A1 Vertaisarvioitu alkuperäisartikkeli tieteellisessä lehdessä

The Human Touch: Using a Webcam to Autonomously Monitor Compliance During Visual Field Assessments




TekijätPete R. Jones, Giorgia Demaria, Iris Tigchelaar, Daniel S. Asfaw, David F. Edgar, Peter Campbell, Tamsin Callaghan, David P. Crabb

KustantajaASSOC RESEARCH VISION OPHTHALMOLOGY INC

Julkaisuvuosi2020

JournalTranslational vision science & technology

Tietokannassa oleva lehden nimiTRANSLATIONAL VISION SCIENCE & TECHNOLOGY

Lehden akronyymiTRANSL VIS SCI TECHN

Artikkelin numeroARTN 31

Vuosikerta9

Numero8

Sivujen määrä14

ISSN2164-2591

eISSN2164-2591

DOIhttps://doi.org/10.1167/tvst.9.8.31

Rinnakkaistallenteen osoitehttps://research.utu.fi/converis/portal/detail/Publication/50333310


Tiivistelmä
Purpose: To explore the feasibility of using various easy-to-obtain biomarkers to monitor non-compliance (measurement error) during visual field assessments.Methods: Forty-two healthy adults (42 eyes) and seven glaucoma patients (14 eyes) underwent two same-day visual field assessments. An ordinary webcam was used to compute seven potential biomarkers of task compliance, based primarily on eye gaze, head pose, and facial expression. We quantified the association between each biomarker and measurement error, as defined by (1) test-retest differences in overall test scores (mean sensitivity), and (2) failures to respond to visible stimuli on individual trials (stimuli -3 dB or more brighter than threshold).Results: In healthy eyes, three of the seven biomarkers were significantly associated with overall (test-retest) measurement error (P = 0.003-0.007), and at least two others exhibited possible trends (P = 0.052-0.060). The weighted linear sum of all seven biomarkers was associated with overall measurement error, in both healthy eyes (r = 0.51, P < 0.001) and patients (r = 0.65, P < 0.001). Five biomarkers were each associated with failures to respond to visible stimuli on individual trials (all P < 0.001).Conclusions: Inexpensive, autonomous measures of task compliance are associated with measurement error in visual field assessments, in terms of both the overall reliability of a test and failures to respond on particular trials ("lapses"). This could be helpful for identifying low-quality assessments and for improving assessment techniques (e.g., by discounting suspect responses or by automatically triggering comfort breaks or encouragement).Translational Relevance: This study explores a potential way of improving the reliability of visual field assessments, a crucial but notoriously unreliable clinical measure.

Ladattava julkaisu

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.





Last updated on 2024-26-11 at 23:10