A1 Refereed original research article in a scientific journal

The Human Touch: Using a Webcam to Autonomously Monitor Compliance During Visual Field Assessments




AuthorsPete R. Jones, Giorgia Demaria, Iris Tigchelaar, Daniel S. Asfaw, David F. Edgar, Peter Campbell, Tamsin Callaghan, David P. Crabb

PublisherASSOC RESEARCH VISION OPHTHALMOLOGY INC

Publication year2020

JournalTranslational vision science & technology

Journal name in sourceTRANSLATIONAL VISION SCIENCE & TECHNOLOGY

Journal acronymTRANSL VIS SCI TECHN

Article numberARTN 31

Volume9

Issue8

Number of pages14

ISSN2164-2591

eISSN2164-2591

DOIhttps://doi.org/10.1167/tvst.9.8.31

Self-archived copy’s web addresshttps://research.utu.fi/converis/portal/detail/Publication/50333310


Abstract
Purpose: To explore the feasibility of using various easy-to-obtain biomarkers to monitor non-compliance (measurement error) during visual field assessments.Methods: Forty-two healthy adults (42 eyes) and seven glaucoma patients (14 eyes) underwent two same-day visual field assessments. An ordinary webcam was used to compute seven potential biomarkers of task compliance, based primarily on eye gaze, head pose, and facial expression. We quantified the association between each biomarker and measurement error, as defined by (1) test-retest differences in overall test scores (mean sensitivity), and (2) failures to respond to visible stimuli on individual trials (stimuli -3 dB or more brighter than threshold).Results: In healthy eyes, three of the seven biomarkers were significantly associated with overall (test-retest) measurement error (P = 0.003-0.007), and at least two others exhibited possible trends (P = 0.052-0.060). The weighted linear sum of all seven biomarkers was associated with overall measurement error, in both healthy eyes (r = 0.51, P < 0.001) and patients (r = 0.65, P < 0.001). Five biomarkers were each associated with failures to respond to visible stimuli on individual trials (all P < 0.001).Conclusions: Inexpensive, autonomous measures of task compliance are associated with measurement error in visual field assessments, in terms of both the overall reliability of a test and failures to respond on particular trials ("lapses"). This could be helpful for identifying low-quality assessments and for improving assessment techniques (e.g., by discounting suspect responses or by automatically triggering comfort breaks or encouragement).Translational Relevance: This study explores a potential way of improving the reliability of visual field assessments, a crucial but notoriously unreliable clinical measure.

Downloadable publication

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.





Last updated on 2024-26-11 at 23:10