A4 Vertaisarvioitu artikkeli konferenssijulkaisussa

A Real-time PPG Quality Assessment Approach for Healthcare Internet-of-Things




TekijätEmad Kasaeyan Naeini, Iman Azimi, Amir M.Rahmani, Pasi Liljeberg, Nikil Dutt

ToimittajaElhadi Shakshuki

Konferenssin vakiintunut nimiInternational Conference on Ambient Systems, Networks and Technologies

KustantajaElsevier B.V.

Julkaisuvuosi2019

JournalProcedia Computer Science

Kokoomateoksen nimiThe 10th International Conference on Ambient Systems, Networks and Technologies (ANT 2019) / The 2nd International Conference on Emerging Data and Industry 4.0 (EDI40 2019) / Affiliated Workshops

Tietokannassa oleva lehden nimiProcedia Computer Science

Vuosikerta151

Aloitussivu551

Lopetussivu558

ISSN1877-0509

DOIhttps://doi.org/10.1016/j.procs.2019.04.074

Rinnakkaistallenteen osoitehttps://research.utu.fi/converis/portal/detail/Publication/42824593


Tiivistelmä

Photoplethysmography (PPG) as a non-invasive and low-cost technique plays a significant role in wearable Internet-of-Things based health monitoring systems, enabling continuous health and well-being data collection. As PPG monitoring is relatively simple, non-invasive, and convenient, it is widely used in a variety of wearable devices (e.g., smart bands, smart rings, smartphones) to acquire different vital signs such as heart rate and pulse rate variability. However, the accuracy of such vital signs highly depends on the quality of the signal and the presence of artifacts generated by other resources such as motion. This unreliable performance is unacceptable in health monitoring systems. To tackle this issue, different studies have proposed motion artifacts reduction and signal quality assessment methods. However, they merely focus on improvements in the results and signal quality. Therefore, they are unable to alleviate erroneous decision making due to invalid vital signs extracted from the unreliable PPG signals. In this paper, we propose a novel PPG quality assessment approach for IoT-based health monitoring systems, by which the reliability of the vital signs extracted from PPG quality is determined. Therefore, unreliable data can be discarded to prevent inaccurate decision making and false alarms. Exploiting a Convolutional Neural Networks (CNN) approach, a hypothesis function is created by comparing heart rate in the PPG with corresponding heart rate values extracted from ECG signal. We implement a proof-of-concept IoT-based system to evaluate the accuracy of the proposed approach.


Ladattava julkaisu

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.





Last updated on 2024-26-11 at 23:32