Pitfalls of femoral Titanium Elastic Nailing




Salonen A, Lahdes-Vasama T, Mattila VM, Valipakka J, Pajulo O

PublisherSAGE PUBLICATIONS LTD

2015

Scandinavian Journal of Surgery

SCANDINAVIAN JOURNAL OF SURGERY

SCAND J SURG

104

2

121

126

6

1457-4969

DOIhttps://doi.org/10.1177/1457496914529275



Conclusions: Based on this study, two types of pitfalls in a small volume center were found. Titanium elastic nail ends were left unbent and too long. We recommend palpating the nail ends to exclude nail prominence and to verify free movement of the knee after nail cutting and bending. Fracture instability was caused by inserting titanium elastic nailing-nails that were too narrow. To avoid this complication, careful preoperative planning to select the proper-size titanium elastic nailing-nails and intraoperative testing of fracture stability under continuous fluoroscopy after the operation is advised.




Last updated on 2024-26-11 at 22:21