A1 Refereed original research article in a scientific journal
Pitfalls of femoral Titanium Elastic Nailing
Authors: Salonen A, Lahdes-Vasama T, Mattila VM, Valipakka J, Pajulo O
Publisher: SAGE PUBLICATIONS LTD
Publication year: 2015
Journal: Scandinavian Journal of Surgery
Journal name in source: SCANDINAVIAN JOURNAL OF SURGERY
Journal acronym: SCAND J SURG
Volume: 104
Issue: 2
First page : 121
Last page: 126
Number of pages: 6
ISSN: 1457-4969
DOI: https://doi.org/10.1177/1457496914529275(external)
Conclusions: Based on this study, two types of pitfalls in a small volume center were found. Titanium elastic nail ends were left unbent and too long. We recommend palpating the nail ends to exclude nail prominence and to verify free movement of the knee after nail cutting and bending. Fracture instability was caused by inserting titanium elastic nailing-nails that were too narrow. To avoid this complication, careful preoperative planning to select the proper-size titanium elastic nailing-nails and intraoperative testing of fracture stability under continuous fluoroscopy after the operation is advised.