A1 Refereed original research article in a scientific journal

Pitfalls of femoral Titanium Elastic Nailing




AuthorsSalonen A, Lahdes-Vasama T, Mattila VM, Valipakka J, Pajulo O

PublisherSAGE PUBLICATIONS LTD

Publication year2015

JournalScandinavian Journal of Surgery

Journal name in sourceSCANDINAVIAN JOURNAL OF SURGERY

Journal acronymSCAND J SURG

Volume104

Issue2

First page 121

Last page126

Number of pages6

ISSN1457-4969

DOIhttps://doi.org/10.1177/1457496914529275(external)


Abstract

Conclusions: Based on this study, two types of pitfalls in a small volume center were found. Titanium elastic nail ends were left unbent and too long. We recommend palpating the nail ends to exclude nail prominence and to verify free movement of the knee after nail cutting and bending. Fracture instability was caused by inserting titanium elastic nailing-nails that were too narrow. To avoid this complication, careful preoperative planning to select the proper-size titanium elastic nailing-nails and intraoperative testing of fracture stability under continuous fluoroscopy after the operation is advised.