A1 Refereed original research article in a scientific journal

A Fine-Tuned Fuzzy-Optimized UNet++ for Retinal Vessel Segmentation;




AuthorsJanardanPatra, Kumar; Mishra, Jibitesh; Dash, Sanjit Kumar; Dash, Sanjit Kumar; Mohapatra, Sudhir Kumar; Heikkonen, Jukka.; Kanth, Rajeev

PublisherInstitute of Electrical and Electronics Engineers (IEEE)

Publication year2026

Journal: IEEE Access

Volume14

First page 74592

Last page74605

eISSN2169-3536

DOIhttps://doi.org/10.1109/ACCESS.2026.3686971

Publication's open availability at the time of reportingOpen Access

Publication channel's open availability Open Access publication channel

Web address https://doi.org/10.1109/access.2026.3686971

Self-archived copy’s web addresshttps://research.utu.fi/converis/portal/detail/Publication/523334629

Self-archived copy's licenceCC BY

Self-archived copy's versionPublisher`s PDF


Abstract
The human eye is a vital organ responsible for vision, and the health of the retina is crucial for preserving sight. Retinal vessel segmentation plays a key role in the early detection of ophthalmic diseases such as diabetic retinopathy, glaucoma, and hypertension, where vascular abnormalities indicate disease progression. This study introduces a novel hybrid framework that enhances vessel segmentation performance using Fuzzy-Optimized UNet++ architecture, demonstrating a 2% improvement over the baseline UNet++ (95.3% accuracy). The proposed method is trained and validated on five benchmark datasets DRIVE, HRF, IOSTAR, ARIA, and CHASE_DB1offering diversity in image resolution, pathology, and vessel morphology to evaluate cross-dataset generalization potential. To address limitations such as class imbalance, noise sensitivity, and poor micro-vessel continuity, we incorporate fuzzy logic for enhanced boundary refinement and Harris Hawks Optimization (HHO) for robust parameter tuning and convergence acceleration. Additionally, a synthetic vessel generation module, VesselGAN, is used to expand dataset diversity, achieving an SSIM score of 0.89 while preserving anatomical accuracy. Comprehensive evaluation is performed using 10-fold cross-validation and external testing on five independent datasets RETA, IDRiD, IOSTAR (external), Kaggle, and clinical-grade images. The integrated approach achieves superior performance across all key metrics, including Dice Coefficient, IoU, SSIM, and F1-score, especially under noisy, low-contrast, and ultra-thin vessel conditions. This research presents a unified, end-to-end system that advances the state-of-the-art in retinal vessel segmentation. Its superior accuracy, resilience to data variability indicates robustness across unseen clinical domains and suggest suitability for real-world deployment in ophthalmic diagnostic systems.


Keywords:
biomedical imagingfuzzy logicHHORetinal VesselU-Net ++Vessel GAN

Downloadable publication

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.





Last updated on 21/05/2026 10:00:27 AM