A1 Vertaisarvioitu alkuperäisartikkeli tieteellisessä lehdessä

Fitting anatomical plates in teenagers with displaced distal radius fractures: A retrospective review;




TekijätSeppänen, Aleksanteri; Pääkkönen, Markus

KustantajaSAGE Publications

Julkaisuvuosi2026

Lehti: Trauma

Artikkelin numero14604086261437231

ISSN1460-4086

eISSN1477-0350

DOIhttps://doi.org/10.1177/14604086261437231

Julkaisun avoimuus kirjaamishetkelläAvoimesti saatavilla

Julkaisukanavan avoimuus Osittain avoin julkaisukanava

Verkko-osoitehttps://doi.org/10.1177/14604086261437231

Rinnakkaistallenteen osoitehttps://research.utu.fi/converis/portal/detail/Publication/523301546

Rinnakkaistallenteen lisenssiCC BY

Rinnakkaistallennetun julkaisun versioKustantajan versio


Tiivistelmä
Background

Distal radius fractures are the most common fractures among adolescents and young adults. In addition to Kirschner wires, after growth plate closure anatomical volar or dorsal radius plates may also be used for fixation. Current volar plates have been designed to fit the wrist of an average adult patient. The aim of this article was to review the use and the suitability of anatomical plates in the treatment of teenagers.

Methods

Retrospective data from patient records was collected on 59 patients, aged from 13 to 19 years, who underwent a plate fixation of distal radius at a tertiary center (level one university trauma hospital). An anatomical plate had been used in 32/59 (54.2%) of the patients. We reviewed and analyzed patient characteristics, injury mechanisms and types, post-operative complication, and pre- and post-operative radiological parameters.

Results

29 wrists were operated using volar and 3 using a dorsal anatomical plate. Anatomical plates had not been used in patients aged ≤14 years. Out of the 29 cases, in 17 (58.6%) wrists the plate positioning corresponded to Soong gr II. In our follow-up period, the incidence of the post-operative complications was not greater than reported among adults. The plate was removed post-operatively in two cases. One removal was done due to inadequate plate positioning causing tendon irritation, and the other due to superficial wound infection.

Conclusions

Kirschner wires should be considered the first line of treatment when operating distal radius fractures in teenagers. Hardware protrusion seems to be common when anatomical volar plates are used. Further research is required to assess the long-term safety and the cumulative rate of complications from the use of anatomical volar plates in teenagers.



Avainsanat:
adolescentdistal radius fracturelocking plate fixationosteosynthesisvolar plate

Ladattava julkaisu

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.




Julkaisussa olevat rahoitustiedot
The authors received no financial support for the research, authorship, and/or publication of this article.