A1 Vertaisarvioitu alkuperäisartikkeli tieteellisessä lehdessä
Label matters: comparing gold nanoparticles and nanoshells with upconversion nanoparticles for quantitative lateral flow immunoassays
Tekijät: Macháčová, Eliška; Máčala, Jakub; Kopecký, Martin; Kuusinen, Saara; Soukka, Tero; Farka, Zdeněk
Julkaisuvuosi: 2026
Lehti: Microchimica Acta
Artikkelin numero: 287
Vuosikerta: 193
Numero: 4
ISSN: 0026-3672
eISSN: 1436-5073
DOI: https://doi.org/10.1007/s00604-026-08015-5
Julkaisun avoimuus kirjaamishetkellä: Avoimesti saatavilla
Julkaisukanavan avoimuus : Osittain avoin julkaisukanava
Verkko-osoite: https://doi.org/10.1007/s00604-026-08015-5
Rinnakkaistallenteen osoite: https://research.utu.fi/converis/portal/detail/Publication/522878357
Rinnakkaistallenteen lisenssi: CC BY
Rinnakkaistallennetun julkaisun versio: Kustantajan versio
Lateral flow immunoassay (LFIA) is a widely used point-of-care method for both qualitative and semi- or fully quantitative detection of clinical biomarkers. There has, however, been limited data available on direct comparison of different types of labels in the LFIA for quantitative analysis using the same non-competitive assay setup. In this study, two groups of antibody-conjugated nanoparticle labels are compared: conventional gold nanostructures with densitometry readout and upconversion nanoparticles (UCNPs) suitable for sensitive luminescence readout. First, the LFIA procedure was optimized using human serum albumin (HSA) as an analyte. In the group of gold-based labels, standard gold nanoparticles were compared with gold nanoshells (AuNSs). In the case of UCNP labels, doping with Er3+ and Tm3+ and surface modifications based on poly(ethylene glycol) and poly(acrylic acid) (PAA) were compared. The best representatives—AuNSs and PAA-Tm UCNPs—were successfully used to detect human serum albumin (HSA) in spiked urine samples. To assess assay versatility, prostate-specific antigen (PSA) was detected in serum. While AuNSs tended to aggregate in serum, the PAA-Tm UCNPs maintained their stability and achieved the limit of detection of 34 pg/mL. Finally, spiked serum samples were analyzed to evaluate detection trueness, achieving a strong correlation with the reference concentrations (recoveries ranging from 82 to 118%). We showed that both label choice and sample matrix are critical: while AuNSs and PAA-Tm UCNPs performed well in urine, PAA-Tm UCNPs excelled in the more complex serum matrix. Thus, PAA-Tm UCNPs were found to be the most suitable labels for biomarker quantitation, highlighting the strong potential of UCNPs for sensitive LFIA applications.
Ladattava julkaisu This is an electronic reprint of the original article. |
Julkaisussa olevat rahoitustiedot:
Open access publishing supported by the institutions participating in the CzechELib Transformative Agreement. This work was supported by projects MUNI/G/1125/2022 and MUNI/C/0091/2025 funded by Masaryk University.