A1 Vertaisarvioitu alkuperäisartikkeli tieteellisessä lehdessä

Does localized irradiance of poly-wave LED influence the bonding performance of universal adhesives to dentin?




TekijätSutil, Elisama; Wendlinger, Michel; Cardenas, Andres Felipe Millan; de Siqueira, Fabiana Suelen Figuerêdo; Soares, Carlos José; Geraldeli, Saulo; Loguercio, Alessandro D.

KustantajaElsevier

Julkaisuvuosi2026

Lehti: Journal of Dentistry

Artikkelin numero106513

Vuosikerta166

ISSN0300-5712

eISSN1879-176X

DOIhttps://doi.org/10.1016/j.jdent.2026.106513

Julkaisun avoimuus kirjaamishetkelläAvoimesti saatavilla

Julkaisukanavan avoimuus Osittain avoin julkaisukanava

Verkko-osoitehttps://doi.org/10.1016/j.jdent.2026.106513

Rinnakkaistallenteen osoitehttps://research.utu.fi/converis/portal/detail/Publication/508917129

Rinnakkaistallenteen lisenssiCC BY

Rinnakkaistallennetun julkaisun versioKustantajan versio


Tiivistelmä
Purpose

This study evaluates how different wavelength ranges emitted by a poly-wave LED curing light violet (405 nm) and blue (445 and 465 nm) affect the microtensile bond strength (μTBS), nanoleakage (NL), and in situ degree of conversion (DC) of universal adhesives applied to dentin.

Methods

Eighty caries-free human molars were randomly assigned to four groups according to two variables: (1) Adhesive system (Ambar Universal APS [AMU], Scotchbond Universal [SBU] and (2) application mode (etch-and-rinse [ER] or self-etch [SE]). To control tooth dependency, each tooth quadrant of every tooth was allocated to a different wavelength range (405, 445 and 465 nm) and identified accordingly during light-curing with the Valo unit (1400 mW/cm2). Afterwards, resin composite fillings were placed, and each quadrant was sectioned to obtain resin-dentin bonded beams (0.8 mm2). These beams were tested for μTBS, NL, and DC. Data for μTBS (MPa), NL (%), and DC (%) were analyzed using three-way ANOVA and Tukey's test (α=5%).

Results

For AMU and SBU, no significant differences were observed among the 445-nm and 465-nm wavelength ranges (p > 0.05) for all outcomes. However, light curing SBU with 405-nm LED resulted in significantly lower μTBS and DC values and higher NL values compared with 445 and 465 nm LEDs (p < 0.01). AMU exhibited higher μTBS and DC values than SBU (p = 0.001). No significant differences were found between SE and ER application strategies (p > 0.05).

Clinical significance

Bonding to dentin may be locally compromised when universal adhesives relying on the conventional camphorquinone/amine photoinitiator system are light-cured with poly-wave LEDs that exhibit non-uniform spectral distribution.


Ladattava julkaisu

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.




Julkaisussa olevat rahoitustiedot
This study was partially supported by the State Foundation of Support to Research, Scientific and Technological Development of Maranhão (FAPEMA) under grant 03628/23 from the State Government of Maranhão Brazil and National Council for Scientific and Technological Development (CNPq) under grant 304444/2025–1 and Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil (CAPES) – Finance Code 001.


Last updated on