A4 Refereed article in a conference publication

Modelling Permafrost Terrain Using Kinematic, Dual-Wavelength Laser Scanning




AuthorsKukko A., Kaartinen H., Osinski G., Hyyppä J.

EditorsN. Paparoditis, C. Mallet, F. Lafarge, F. Remondino, I. Toschi, T. Fuse

Conference nameISPRS Congress

PublisherCopernicus GmbH

Publication year2020

Journal: ISPRS Annals of the Photogrammetry, Remote Sensing and Spatial Information Sciences

Book title XXIV ISPRS Congress, Commission II (Volume V-2-2020)

Journal name in sourceISPRS Annals of the Photogrammetry, Remote Sensing and Spatial Information Sciences

VolumeV-2-2020

First page 749

Last page756

ISSN2194-9042

eISSN2194-9042

DOIhttps://doi.org/10.5194/isprs-annals-V-2-2020-749-2020

Self-archived copy’s web addresshttps://research.utu.fi/converis/portal/detail/Publication/50887930


Abstract

In this paper we introduce the first dual-wavelength, kinematic backpack laser scanning system and its application on high resolution 3D terrain modelling of permafrost landforms. We discuss the data processing pipeline from acquisition to preparation, system calibration and terrain model process. Topographic information is vital for planning and monitoring tasks in urban planning, road construction for mass calculations, and mitigation of flood and wind related risks by structural design in coastal areas. 3D data gives possibility to understand natural processes inducing changes in the terrain, such as the cycles of thaw-freeze in permafrost regions. Through an application case on permafrost landforms in the Arctic we present the field practices and data processing applied, characterize the data output and discuss the precision and accuracy of the base station, trajectory and point cloud data. Two pulsed time of flight ranging, high performance mobile laser scanners were used in combination with a near navigation grade GNSS-IMU positioning on a kinematic backpack platform. The study shows that with a high-end system 15 mm absolute accuracy of 3D data could be achieved using PPP processing for the GNSS base station and multi-pass differential trajectory post-processing. The PPP solution shows millimetre level agreement (Easting 6 mm, Northing 4 mm, and elevation 8 mm standard deviations) for the base station coordinates over an 11 day period. The point cloud residual standard deviation for angular boresight misalignment was 27 mm. The absolute distance between ground surfaces from interactive analysis was 17 mm with 13 mm standard deviation (n = 64). The proposed backpack laser scanning provides accurate and precise 3D data and performance over considerable land surface area for detailed elevation modelling and analysis of the morphology of features of interest. The high density point cloud data permits fusion of the dual-wavelength lidar reflectance data into spectral products.


Downloadable publication

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.





Last updated on 26/11/2024 10:34:39 PM