A1 Refereed original research article in a scientific journal

Midline denture base strains of glass fiber-reinforced single implant-supported overdentures




AuthorsGibreel Mona, Lassila Lippo V. J., Närhi Timo O., Perea-Lowery Leila, Vallittu Pekka K.

PublisherMosby Inc.

Publication year2021

JournalJournal of Prosthetic Dentistry

Journal name in sourceJournal of Prosthetic Dentistry

Volume126

Issue3

First page 407

Last page412

eISSN1097-6841

DOIhttps://doi.org/10.1016/j.prosdent.2020.05.018

Self-archived copy’s web addresshttps://research.utu.fi/converis/portal/detail/Publication/50847802


Abstract

Statement of problem

The fracture incidence of implant-supported overdentures is more frequent in the area of attachment because of stress concentration and denture deformation in this area. How E-glass fiber reinforcement can address this problem is unclear.

Purpose

The purpose of this in vitro study was to evaluate the influence of unidirectional E-glass fiber reinforcement on the mid-line denture base strains of single implant-supported overdentures.

Material and methods

An experimental acrylic resin cast was constructed with a single implant placed in the mid-line area and a ball attachment screwed to the implant. Twenty-four experimental overdentures were constructed and divided into 4 groups: group AP fabricated from autopolymerizing acrylic resin without fiber reinforcement, group APF fabricated from autopolymerizing acrylic resin with unidirectional E-glass fiber reinforcement running over the residual ridge and the ball matrix, group HP fabricated from heat-polymerized acrylic resin without fiber reinforcement, and group HPF fabricated from heat-polymerized acrylic resin with unidirectional E-glass fiber reinforcement running over the residual ridge and the ball matrix. A biaxial rosette strain gauge was attached to the incisor areas of each overdenture above the attachment level (Ch1, Ch2) and to a multichannel digital strain meter. A static vertical load of 100 N was applied to the first molar area bilaterally by using a universal testing device during strain measurement procedures. The differences in the mean strain and deflection values among the investigated groups were evaluated for statistical significance using 1-way analysis of variance (ANOVA) with the Tukey post hoc multiple comparison (α=.05).

Results

The type of acrylic resin did not have a statistically significant effect on the mean strain values among groups (P=.350), while the reinforcement did significantly affect them (P<.001). The interaction between reinforcement and acrylic resin was not statistically significant (P=.552). Both strain gauge channels in group APF and group HPF recorded significantly lower strain values by almost 50% than those of group AP and group HP (P<.05).

Conclusions

Unidirectional E-glass fiber reinforcement placed over the residual ridge and implant attachment significantly reduced denture base strains and deformation of single implant-supported overdentures.


Downloadable publication

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.





Last updated on 2024-26-11 at 22:33