A1 Vertaisarvioitu alkuperäisartikkeli tieteellisessä lehdessä

Shared-optical-path VLBI frequency phase transfer from 86 to 258 GHz on an 8600km baseline: Demonstrated with the APEX and IRAM 30m telescopes




TekijätZhao, G. -Y; Roy, A. L.; Wagner, J. F.; Donoso, E.; Torne, P.; Ros, E.; Lindqvist, M.; Lobanov, A. P.; Ramakrishnan, V.; Krichbaum, T. P.; Rottmann, H.; Zensus, J. A.; Perez-beaupuits, J. P.; Klein, B.; Menten, K. M.; Ricken, O.; Reyes, N.; Sanchez, S.; Ruiz, I.; Duran, C.; John, D.; Santaren, J. L.; Sanchez-portal, M.; Bremer, M.; Kramer, C.; Schuster, K. F.; Rioja, M. J.; Dodson, R.

KustantajaEDP Sciences

Julkaisuvuosi2025

Lehti:Astronomy and Astrophysics

Artikkelin numeroA132

Vuosikerta701

ISSN0004-6361

eISSN1432-0746

DOIhttps://doi.org/10.1051/0004-6361/202555346

Verkko-osoitehttps://doi.org/10.1051/0004-6361/202555346

Rinnakkaistallenteen osoitehttps://research.utu.fi/converis/portal/detail/Publication/504924562


Tiivistelmä

Context

The receiver N3AR operating at a frequency range between 67 and 116 GHz was commissioned at the APEX telescope in October 2024. It adds a new low-frequency band for APEX, with the capability of simultaneous dual-frequency observations using a dichroic beamsplitter. The 3 mm receiver also allows APEX to join the existing 3 mm global very long baseline interferometry (VLBI) network.

Aims

One of our commissioning goals was to perform simultaneous dual-band VLBI observations at 86 and 258 GHz using receivers with shared optical paths (SOPs) to correct the atmospheric phase fluctuations using the frequency phase transfer (FPT) technique. This was possible together with the IRAM 30 m telescope, which has already developed such a capability. We aimed to verify the expected phase coherence and sensitivity improvement at the higher frequency achievable by applying FPT.

Methods

With the dual-band, single baseline data, we applied the FPT method, which uses the lower-frequency data to correct the simultaneously observed higher-frequency data. We evaluated the improvement compared to the conventional single-band observing mode by analyzing the coherence factor in the higher-frequency data.

Results

Our results show that the phase fluctuations at the two bands correlate well. After applying FPT, the interferometric phases at the higher frequency vary much less, and the coherence factor is significantly improved.

Conclusions

Our analysis confirms the feasibility of applying FPT to frequencies above 250 GHz with SOP receivers. Future observations in this mode could dramatically improve the sensitivity and imaging fidelity of high-frequency VLBI.


Ladattava julkaisu

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.




Julkaisussa olevat rahoitustiedot
This work was supported by the European Union Horizon 2020 research and innovation programme under grant agreements RadioNet (No. 730562), M2FINDERS (No. 101018682). Open Access funding provided by Max Planck Society.


Last updated on 2025-23-10 at 11:14