A1 Refereed original research article in a scientific journal

Quality of anticoagulation and outcomes after mechanical aortic valve replacement in patients with atrial fibrillation: a nationwide cohort study




AuthorsLehto, Joonas; Björn, Rikhard; Halminen, Olli; Linna, Miika; Haukka, Jari; Putaala, Jukka; Mustonen, Pirjo; Kinnunen, Janne; Hartikainen, Juha; Airaksinen, Juhani K E; Kiviniemi, Tuomas O; Lehto, Mika

PublisherOxford University Press (OUP)

Publishing placeOXFORD

Publication year2025

JournalEuropean Heart Journal - Quality of Care and Clinical Outcomes

Journal name in sourceEuropean Heart Journal - Quality of Care and Clinical Outcomes

Journal acronymEUR HEART J-QUAL CAR

Volume11

Issue5

First page 654

Last page664

Number of pages11

ISSN2058-5225

eISSN2058-1742

DOIhttps://doi.org/10.1093/ehjqcco/qcaf028

Web address https://doi.org/10.1093/ehjqcco/qcaf028

Self-archived copy’s web addresshttps://research.utu.fi/converis/portal/detail/Publication/498626908


Abstract

Aims: Mechanical aortic valve replacement (AVR) remains the primary treatment for younger patients with severe aortic valve disease. However, limited information is available regarding the quality of the required lifelong vitamin K antagonist (VKA) therapy, atrial fibrillation (AF), and their relationship with adverse events after AVR. This study assessed the quality of VKA therapy prior to bleeding and ischaemic events following mechanical AVR in patients with AF.

Methods and results: The registry-based Finnish AntiCoagulation in Atrial Fibrillation study combining data from several Finnish healthcare registers covers all patients diagnosed with AF during 2007-18 in Finland. This analysis included patients undergoing mechanical AVR before or after the AF diagnosis. A total of 1086 patients with mechanical AVR and AF either before (41.2%) or after (58.8%) the operation were identified. Cumulative incidence estimates at 10 years after AVR were 27.9% for significant bleeding, 5.8% for intracranial haemorrhage, 12.8% for ischaemic stroke, and 7.2% for myocardial infarction. Time in therapeutic range (TTR) < 80% with international normalized ratio (INR) target 2.0-3.5 was associated with higher bleeding occurrence [adjusted hazard ratio (aHR) 1.97, 1.39-2.79, P < 0.001]. Time in therapeutic range with INR target ≥2.0 was associated with higher stroke occurrence (aHR/standard deviation 1.22, 1.01-1.46, P = 0.035). Mortality was high (28.9%/10 years), and TTR <80% was associated with higher mortality (aHR 2.74, 2.00-3.76, P < 0.001).

Conclusion: Adverse events, particularly major bleeding, are common in patients with AF following mechanical AVR, and mortality is high. Suboptimal TTR appears to predict bleeding episodes, ischaemic stroke, and death, and it could be useful in high-risk patient identification and targeting of preventive strategies.


Downloadable publication

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.




Funding information in the publication
This work was supported by the Aarne Koskelo Foundation, the Finnish Foundation for Cardiovascular Research (T.O.K. and M.L.), and Hospital District of Helsinki and Uusimaa (TYH2019309).


Last updated on 2025-22-08 at 13:51