A1 Vertaisarvioitu alkuperäisartikkeli tieteellisessä lehdessä
Measuring bone metabolic activity in dialysis patients with renal osteodystrophy using [18F]-Sodium Fluoride positron emission tomography- comparison between static and dynamic measurements
Tekijät: Aaltonen, Louise; Koivuviita, Niina; Seppänen, Marko; Oikonen, Vesa; Kirjavainen, Anna K.; Kröger, Heikki; Löyttyniemi, Eliisa; Metsärinne, Kaj
Kustantaja: Springer Science and Business Media LLC
Kustannuspaikka: LONDON
Julkaisuvuosi: 2025
Journal: BMC Nephrology
Tietokannassa oleva lehden nimi: BMC Nephrology
Lehden akronyymi: BMC NEPHROL
Artikkelin numero: 170
Vuosikerta: 26
Numero: 1
Sivujen määrä: 9
eISSN: 1471-2369
DOI: https://doi.org/10.1186/s12882-025-04063-w
Verkko-osoite: https://doi.org/10.1186/s12882-025-04063-w
Rinnakkaistallenteen osoite: https://research.utu.fi/converis/portal/detail/Publication/491809982
Background: Dynamic [18F]NaF PET has shown promising results in the measurement of bone metabolism in patients with renal osteodystrophy. Dynamic PET scans are challenging in clinical practice, and the objective of this study was to evaluate whether standardized uptake values measured by [18F]NaF PET could be a feasible method.
Methods: Twenty-eight patients on maintenance dialysis with confirmed renal osteodystrophy underwent a dynamic [18F]NaF PET scan. As a reference for bone metabolism, a bone biopsy was obtained from the anterior iliac crest (AIC). Tracer activity in bone was measured using Patlak analysis and standardized uptake values (SUV). SUV was also adjusted to tracer activity measured from the aorta 48-60 min after injection (SUVR).
Results: SUV measured in the lumbar spine (L1-L4) and at the AIC did not correlate with histomorphometric parameters obtained by bone biopsy. There was no statistically significant difference between SUV in different turnover groups. When adjusting the mean bone uptake of fluoride in the lumbar spine, there was a strong correlation with the blood clearance of tracer to bone (Ki). SUVR also correlated significantly with histomorphometric markers obtained by bone biopsy.
Conclusions: These results suggest that measurements of tracer activity in the blood 48-60 min after tracer injection could be used to correct SUVs from static [18F]NaF PET scans. However, further research and validation of the method is needed.
Ladattava julkaisu This is an electronic reprint of the original article. |
Julkaisussa olevat rahoitustiedot:
This work was supported by the Finska Läkaresällskapet, Munuaissäätiö and the Perklén Foundation, Helsinki, Finland.