A1 Vertaisarvioitu alkuperäisartikkeli tieteellisessä lehdessä

Plaque burden improves the detection of ischemic CAD over stenosis from coronary computed tomography angiography




TekijätKero, Tanja; Bär, Sarah; Saraste, Antti; Klén, Riku; Bax, Jeroen J.; Knuuti, Juhani; Maaniitty, Teemu

KustantajaSpringer Nature

KustannuspaikkaDORDRECHT

Julkaisuvuosi2025

JournalInternational Journal of Cardiovascular Imaging

Tietokannassa oleva lehden nimiThe International Journal of Cardiovascular Imaging

Lehden akronyymiINT J CARDIOVAS IMAG

Sivujen määrä10

ISSN1569-5794

eISSN1875-8312

DOIhttps://doi.org/10.1007/s10554-025-03396-9

Verkko-osoitehttps://doi.org/10.1007/s10554-025-03396-9

Rinnakkaistallenteen osoitehttps://research.utu.fi/converis/portal/detail/Publication/491757330


Tiivistelmä

In symptomatic patients undergoing coronary CTA for suspected coronary artery disease (CAD), we assessed if quantification of plaque burden, in addition to luminal narrowing and clinical risk factors, offers incremental value for the identification of ischemic CAD on a per patient level. We evaluated 2145 patients who underwent coronary CTA for suspected CAD with sequential selective downstream 15O-water positron emission tomography (PET) myocardial perfusion imaging. Coronary CTA scans were analyzed using Artificial Intelligence-guided Quantitative Computed Tomography (AI-QCT), with measurement of maximum diameter stenosis, percent atheroma volume (PAV), percent calcified plaque volume (CPV) and percent noncalcified plaque volume (NCPV). Ischemic CAD was defined as the presence of abnormal stress perfusion on 15O-water PET. PAV on top of the clinical variables and ≥ 50% stenosis improved the prediction of ischemic CAD on a per patient level as compared to clinical variables and ≥ 50% stenosis (AUC = 0.91 vs. AUC = 0.87, p < 0.001). The best diagnostic performance was achieved when PAV with a cut-off value of 12.2% was applied in patients with intermediate (30-70%) stenosis; using this approach, the sensitivity, specificity, positive and negative predictive values and diagnostic accuracy for ischemic CAD were 76%, 91%, 64%, 95% and 88%. The addition of quantitative plaque volume on top of clinical variables and ≥ 50% diameter stenosis improves the detection of ischemic CAD as defined by PET perfusion imaging. Applying a PAV threshold of 12.2% in patients with intermediate stenosis provided the best diagnostic performance.


Ladattava julkaisu

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.




Julkaisussa olevat rahoitustiedot
Open Access funding provided by University of Turku (including Turku University Central Hospital). The study was funded by the Finnish Foundation for Cardiovascular Research, the Research Council of Finland, and Finnish State Research Funding [VTR 13403]. Dr. Bär was supported by the Swiss National Science Foundation [P500PM_210788] and the University of Turku, Finland. Cleerly Inc. performed the image analysis without costs and
provided an unrestricted research grant for the University of Turku.


Last updated on 2025-19-05 at 17:01