A1 Vertaisarvioitu alkuperäisartikkeli tieteellisessä lehdessä

Respiration Rate Estimation via Smartwatch-based Photoplethysmography and Accelerometer Data: A Transfer Learning Approach




TekijätKazemi, Kianoosh; Azimi, Iman; Liljeberg, Pasi; Rahmani, Amir M.

KustantajaAssociation for Computing Machinery

KustannuspaikkaNEW YORK

Julkaisuvuosi2025

JournalProceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies

Tietokannassa oleva lehden nimiPROCEEDINGS OF THE ACM ON INTERACTIVE MOBILE WEARABLE AND UBIQUITOUS TECHNOLOGIES-IMWUT

Lehden akronyymiPROC ACM INTERACT MO

Artikkelin numero7

Vuosikerta9

Numero1

Sivujen määrä24

eISSN2474-9567

DOIhttps://doi.org/10.1145/3712280

Verkko-osoitehttps://doi.org/10.1145/3712280

Rinnakkaistallenteen osoitehttps://research.utu.fi/converis/portal/detail/Publication/491741756


Tiivistelmä
Respiration Rate (RR) is a biomarker for several illnesses that can be extracted from biosignals, such as photoplethysmogram (PPG) and accelerometers. Smartwatch-based PPG signals are more prone to noise interference, particularly within their lower frequency spectrum where respiratory data is embedded. Therefore, existing methods are insufficient for extracting RR from PPG data collected from wrists reliably. Additionally, accelerometer sensors embedded in smartwatches capture respiration-induced motion and can be integrated with PPG signals to improve RR extraction. This paper proposes a deep learning-based model to extract RR from raw PPG and accelerometer signals captured via a smartwatch. The proposed network combines dilated residual inception module and Multi-Scale convolutions. We propose a pre-trained foundation model for smartwatch-based RR extraction and apply a transfer learning technique to enhance the generalizability of our method across different datasets. We test the proposed method using two public datasets (i.e., WESAD and PPG-DaLiA). The proposed method shows the Mean Absolute Error (MAE) of 2.29 and 3.09 and Root Mean Squared Errors (RMSE) of 3.11 and 3.79 across PPG-DaLiA and WESAD datasets, respectively. In contrast, the best results obtained by the existing methods are an MAE of 2.68, an RMSE of 3.5 for PPG-DaLiA, an MAE of 3.46, and an RMSE of 4.02 for WESAD datasets.

Ladattava julkaisu

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.




Julkaisussa olevat rahoitustiedot
This work was partially supported by the Finnish Foundation for Technology Promotion and the Nokia Foundation.


Last updated on 2025-08-05 at 14:01