A1 Vertaisarvioitu alkuperäisartikkeli tieteellisessä lehdessä

Comparison of Sedentary Time Between Thigh-Worn and Wrist-Worn Accelerometers




TekijätKristin Suorsa, Anna Pulakka, Tuija Leskinen, Jaana Pentti, Andreas Holtermann, Olli J. Heinonen, Juha Sunikka, Jussi Vahtera, Sari Stenholm

KustantajaHuman Kinetics Journals

Julkaisuvuosi2020

JournalJournal for the Measurement of Physical Behaviour

Vuosikerta3

Numero3

Aloitussivu234

Lopetussivu243

DOIhttps://doi.org/10.1123/jmpb.2019-0052

Verkko-osoitehttps://doi.org/10.1123/jmpb.2019-0052

Rinnakkaistallenteen osoitehttps://research.utu.fi/converis/portal/detail/Publication/48509458


Tiivistelmä

Background: The accuracy of wrist-worn accelerometers in identifying sedentary time has been scarcely studied in free-living conditions. The aim of this study was to compare daily sedentary time estimates between a thigh-worn accelerometer, which measured sitting and lying postures, and a wrist-worn accelerometer, which measured low levels of movement. Methods: The study population consisted of 259 participants (Mage = 62.8 years, SD = 0.9) from the Finnish Retirement and Aging Study (FIREA). Participants wore an Axivity AX3 accelerometeron their mid-thigh and an Actigraph wActiSleep-BT accelerometer on their non-dominant wrist simultaneously for a minimum of 4 days in free-living conditions. Two definitions to estimate daily sedentary time were used for data from the wrist-worn accelerometer: 1) the count cutpoint, ≤1853 counts per minute; and 2) the Euclidean Norm Minus One (ENMO) cutpoint, <30 mg. Results: Compared to the thigh-wornaccelerometer, daily sedentary time estimate was 63 min (95% confidence interval [CI] = −53 to −73) lower by the count cutpoint and 50 min (95% CI = 34 to 67) lower by the ENMO cutpoint. The limits of agreement in daily sedentary time estimates between the thigh- and cutpoint methods for wrist-worn accelerometers were wide (the count cutpoint: −117 to 243, the ENMO cutpoint: −212 to 313 min). Conclusions: Currently established cutpoint-based methods to estimate sedentary time from wrist-worn accelerometers result in underestimation of daily sedentary time compared to posture-based estimates of thigh-worn accelerometers. Thus, sedentary time estimates obtained from wrist-worn accelerometers using currently available cutpoint-based methods should be interpreted with caution and future work is needed to improve their accuracy.


Ladattava julkaisu

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.





Last updated on 2024-26-11 at 20:28