A2 Refereed review article in a scientific journal

Self-monitoring of blood pressure in patients with hypertension related multi-morbidity: Systematic review and individual patient data meta-analysis




AuthorsSheppard JP, Tucker KL, Davison WJ, Stevens R, Aekplakorn W, Bosworth HB, Bove A, Earle K, Godwin M, Green BB, Hebert P, Heneghan C, Hill N, Hobbs FDR, Kantola I, Leiva A, Kerry SM, Mant J, Magid DJ, McKinstry B, Margolis KL, McNamara K, McLaughlin MA, Ogedegbe O, Omboni S, Varis J, Parati G, Wakefield BJ, Verberk WJ, McManus RJ

PublisherOxford University Press

Publication year2020

JournalAmerican Journal of Hypertension

Journal name in sourceAmerican journal of hypertension

Journal acronymAm J Hypertens

Volume33

First page 243

Last page251

ISSN0895-7061

eISSN1941-7225

DOIhttps://doi.org/10.1093/ajh/hpz182

Self-archived copy’s web addresshttps://research.utu.fi/converis/portal/detail/Publication/45541245


Abstract

BACKGROUND



Studies have shown that self-monitoring of blood pressure
(BP) is effective when combined with co-interventions, but its efficacy varies
in the presence of some co-morbidities. This study examined whether
self-monitoring can reduce clinic BP in patients with hypertension-related
co-morbidity.



METHODS



A systematic review was conducted of articles published in
Medline, Embase, and the Cochrane Library up to January 2018. Randomized
controlled trials of self-monitoring of BP were selected and individual patient
data (IPD) were requested. Contributing studies were prospectively categorized
by whether they examined a low/high-intensity co-intervention. Change in BP and
likelihood of uncontrolled BP at 12 months were examined according to number
and type of hypertension-related co-morbidity in a one-stage IPD meta-analysis.



RESULTS



A total of 22 trials were eligible, 16 of which were able to
provide IPD for the primary outcome, including 6,522 (89%) participants with
follow-up data. Self-monitoring was associated with reduced clinic systolic BP
compared to usual care at 12-month follow-up, regardless of the number of
hypertension-related co-morbidities (−3.12 mm Hg, [95% confidence intervals
−4.78, −1.46 mm Hg]; P value for interaction with number of morbidities = 0.260).
Intense interventions were more effective than low-intensity interventions in
patients with obesity (P < 0.001 for all outcomes), and possibly stroke (P
< 0.004 for BP control outcome only), but this effect was not observed in
patients with coronary heart disease, diabetes, or chronic kidney disease.



CONCLUSIONS



Self-monitoring lowers BP regardless of the number of
hypertension-related co-morbidities, but may only be effective in conditions
such obesity or stroke when combined with high-intensity co-interventions.


Downloadable publication

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.





Last updated on 2024-26-11 at 19:59