A1 Refereed original research article in a scientific journal

Survival of 11,390 Continuum cups in primary total hip arthroplasty based on data from the Finnish Arthroplasty Register




AuthorsHemmilä M, Karvonen M, Laaksonen I, Matilainen M, Eskelinen A, Haapakoski J, Puhto AP, Kettunen J, Manninen M, Mäkelä KT

PublisherTAYLOR & FRANCIS LTD

Publication year2019

Journal: Acta Orthopaedica

Journal name in sourceACTA ORTHOPAEDICA

Journal acronymACTA ORTHOP

Volume90

Issue4

First page 312

Last page317

Number of pages6

ISSN1745-3674

eISSN1745-3682

DOIhttps://doi.org/10.1080/17453674.2019.1603596

Self-archived copy’s web addresshttps://research.utu.fi/converis/portal/detail/Publication/40256586


Abstract
Background and purpose - The use of trabecular metal (TM) cups for primary total hip arthroplasty (THA) is increasing. Some recent data suggest that the use of TM in primary THA might be associated with an increased risk of revision. We compared implant survival of Continuum acetabular cups with other commonly used uncemented cups. Patients and methods - Data on 11,390 primary THAs with the Continuum cup and 30,372 THAs with other uncemented cups (reference group) were collected from the Finnish Arthroplasty Register. Kaplan-Meier survival estimates were calculated; the endpoint was revision for any reason, for infection, or for dislocation. Revision risks were assessed with adjusted Cox multiple regression models. A subgroup analysis on the use of neutral or elevated liners in the Continuum group was made. Results - The 7-year survivorship of the Continuum group was 94.6% (95% CI 94.0-95.2) versus 95.6% (CI 95.3-95.8) in the reference group for revision for any reason. The risk for revision was higher in the Continuum group than in the reference group both for revision for any reason (HR 1.3 [CI 1.2-1.5)]) and for revision for dislocation (HR 1.9 [CI 1.5-2.3]). There was no difference in the rates of revision because of infection (HR 0.99 [CI 0.78-1.3]). Use of a neutral liner increased the risk for revision due to dislocation in comparison with the use of an elevated rim liner in the Continuum group (HR 1.7 [CI 1.2-2.5]). Interpretation - THA with Continuum cups is associated with an increased risk of revision compared with other uncemented cups, mainly due to revisions because of dislocation. Our results support the use of an elevated liner when Continuum cups are used for primary THA.

Downloadable publication

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.





Last updated on 26/11/2024 10:56:04 PM