A1 Refereed original research article in a scientific journal

Three modes of electrochemical impedance spectroscopy measurements performed on vanadium redox flow battery




AuthorsKrakowiak Joanna, Bącalski Wojciech, Lentka Grzegorz, Peljo Pekka, Ślepski Paweł

PublisherElsevier

Publication year2024

JournalSustainable Materials and Technologies

Journal name in sourceSustainable Materials and Technologies

Article numbere00957

Volume40

ISSN2214-9937

eISSN2214-9937

DOIhttps://doi.org/10.1016/j.susmat.2024.e00957

Web address https://doi.org/10.1016/j.susmat.2024.e00957

Self-archived copy’s web addresshttps://research.utu.fi/converis/portal/detail/Publication/393426548


Abstract
This article presents an innovative approach to monitor working redox flow batteries using dynamic electrochemical impedance spectroscopy, diverging from the commonly sequential impedance methods carried out under potentiostatic or galvanostatic conditions close to the open circle voltage. The authors introduce a fresh variation of dynamic impedance measurement that leverages an amplitude-modulated multi-frequency alternating current perturbation signal. This technique leads to a reduction in measurement time, making it possible to monitor impedance in real-time under typical operational conditions. Consequently, it effectively addresses the limitations stemming from the absence of stationary conditions during impedance measurements. There is no doubt that measurement techniques enabling the study of processes during the operational life of a battery provide the most valuable insights into the properties of these systems. The potential of this proposed approach is exemplified through the examination of a full vanadium redox flow battery as a case study. Classical impedance measurements were also conducted under potentiostatic and galvanostatic conditions with sequential frequency signal change, which requires stopping the battery operation, resulting in electrode potential changes of over 200 mV compared to the working system. Spectra for all modes of measurements were compared. In the case of dynamic measurements, such significant differences in spectra during charging and discharging are not observed, which is characteristic of classical measurements. The authors deliberately and consciously refrain from analyzing the results by fitting equivalent circuits.

Downloadable publication

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.





Last updated on 2025-06-05 at 09:38