A1 Refereed original research article in a scientific journal
Effect of resin composite shade on digital fiber-optic transillumination imaging in vitro
Authors: Ishida Yoshiki, Miura Daisuke, Shinya Akikazu
Publication year: 2023
Journal: Odontology
Journal name in source: Odontology
Journal acronym: Odontology
Volume: 111
Issue: 4
First page : 854
Last page: 862
ISSN: 1618-1247
eISSN: 1618-1255
DOI: https://doi.org/10.1007/s10266-023-00792-2
Publication's open availability at the time of reporting: No Open Access
Publication channel's open availability : Partially Open Access publication channel
Web address : https://doi.org/10.1007/s10266-023-00792-2
Abstract
Digital imaging fiber-optic transillumination (DIFOTI) devices have been used to detect caries, a technique without using X-rays. However, the effects of resin composites (RCs) shades on the images acquired with DIFOTI devices have not been investigated. Thus, this study aimed to elucidate the influence of RC shade on the images obtained with DIFOTI technique. Three shades (A1, A3, and Opaque) for each of four flowable RCs were filled on a cavity prepared in a left mandibular first premolar obtained from a donated body. Then, transmission images with a DIFOTI device (DIAGNOcam; KaVo, Biberach, Germany) were acquired, and the average lightness values of the images in the RC and enamel were used to calculate differences between those areas. To clarify the influence of the optical translucency and color on DIFOTI images, the color parameters (L*, a* and b*) of each RC were obtained with black and white backgrounds. The color differences between the backgrounds were calculated as transparency parameter (TP) values. The number of repetitions was set to 10. Differences in the lightness value of the shades varied in each RC. The difference in lightness was significantly associated with the TP value and color parameters of L* (p < 0.01), with negative (R = - 0.81) and positive (R = 0.84) correlations, respectively. In conclusion, DIFOTI images of RCs with high optical translucency resembled those of the natural tooth structure.
Digital imaging fiber-optic transillumination (DIFOTI) devices have been used to detect caries, a technique without using X-rays. However, the effects of resin composites (RCs) shades on the images acquired with DIFOTI devices have not been investigated. Thus, this study aimed to elucidate the influence of RC shade on the images obtained with DIFOTI technique. Three shades (A1, A3, and Opaque) for each of four flowable RCs were filled on a cavity prepared in a left mandibular first premolar obtained from a donated body. Then, transmission images with a DIFOTI device (DIAGNOcam; KaVo, Biberach, Germany) were acquired, and the average lightness values of the images in the RC and enamel were used to calculate differences between those areas. To clarify the influence of the optical translucency and color on DIFOTI images, the color parameters (L*, a* and b*) of each RC were obtained with black and white backgrounds. The color differences between the backgrounds were calculated as transparency parameter (TP) values. The number of repetitions was set to 10. Differences in the lightness value of the shades varied in each RC. The difference in lightness was significantly associated with the TP value and color parameters of L* (p < 0.01), with negative (R = - 0.81) and positive (R = 0.84) correlations, respectively. In conclusion, DIFOTI images of RCs with high optical translucency resembled those of the natural tooth structure.