The development of two different immunoassays for the determination of fumonisin B-1 in wheat samples is reported. A previously described mimopeptide for fumonisin B-1 (FB1) was used to produce fusion proteins in combination with two different luciferases: Gaussia luciferase (GLuc) and NanoLuc luciferase (NLuc). The production, expression and the development of two immunoassays based on these fusion proteins (A2-GLuc and A2-NLuc) is detailed. The assay showing the best performance, A2-NLuc, with a limit of detection of 0.61ngmL(-1) and a dynamic range from 1.9 to 95ngmL(-1), was employed for the analysis of spiked wheat samples, a reference matrix material, as well as naturally contaminated wheat samples. The recoveries obtained in the spiked samples were acceptable, between 81.5 and 109%, with relative standard deviations lower than 14%. The analysis of naturally contaminated wheat was validated by a liquid chromatography coupled to tandem mass detection method.