A4 Vertaisarvioitu artikkeli konferenssijulkaisussa
IoT-based continuous glucose monitoring system: A feasibility study
Tekijät: Gia TN, Ali M, Ben Dhaou I, Rahmani AM, Westerlund T, Liljeberg P, Tenhunen H
Toimittaja: Shakshuki, E
Konferenssin vakiintunut nimi: International Conference on Ambient Systems, Networks and Technologies
Julkaisuvuosi: 2017
Journal: Procedia Computer Science
Kokoomateoksen nimi: 8th International Conference on Ambient Systems, Networks and Technologies (ANT) / 7th International Conference on Sustainable Energy Information Technology (SEIT)
Tietokannassa oleva lehden nimi: 8TH INTERNATIONAL CONFERENCE ON AMBIENT SYSTEMS, NETWORKS AND TECHNOLOGIES (ANT-2017) AND THE 7TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY INFORMATION TECHNOLOGY (SEIT 2017)
Lehden akronyymi: PROCEDIA COMPUT SCI
Vuosikerta: 109
Aloitussivu: 327
Lopetussivu: 334
Sivujen määrä: 8
ISSN: 1877-0509
DOI: https://doi.org/10.1016/j.procs.2017.05.359
Rinnakkaistallenteen osoite: https://research.utu.fi/converis/portal/detail/Publication/28460710
Health monitoring systems based on Internet-of-things (IoT) have been recently introduced to improve the quality of health care services. However, the number of advanced IoT-based continuous glucose monitoring systems is small and the existing systems have several limitations. In this paper we study feasibility of invasive and continuous glucose monitoring (CGM) system utilizing IoT based approach. We designed an IoT-based system architecture from a sensor device to a back-end system for presenting real-time glucose, body temperature and contextual data (i.e. environmental temperature) in graphical and human-readable forms to end-users such as patients and doctors. In addition, nRF communication protocol is customized for suiting to the glucose monitoring system and achieving a high level of energy efficiency. Furthermore, we investigate energy consumption of the sensor device and design energy harvesting units for the device. Finally, the work provides many advanced services at a gateway level such as a push notification service for notifying patient and doctors in case of abnormal situations (i.e. too low or too high glucose level). The results show that our system is able to achieve continuous glucose monitoring remotely in real-time. In addition, the results reveal that a high level of energy efficiency can be achieved by applying the customized nRF component, the power management unit and the energy harvesting unit altogether in the sensor device. 1877-0509 (C) 2017 The Authors. Published by Elsevier B.V.
Ladattava julkaisu This is an electronic reprint of the original article. |