A4 Vertaisarvioitu artikkeli konferenssijulkaisussa

IoT-based continuous glucose monitoring system: A feasibility study




TekijätGia TN, Ali M, Ben Dhaou I, Rahmani AM, Westerlund T, Liljeberg P, Tenhunen H

ToimittajaShakshuki, E

Konferenssin vakiintunut nimiInternational Conference on Ambient Systems, Networks and Technologies

Julkaisuvuosi2017

JournalProcedia Computer Science

Kokoomateoksen nimi8th International Conference on Ambient Systems, Networks and Technologies (ANT) / 7th International Conference on Sustainable Energy Information Technology (SEIT)

Tietokannassa oleva lehden nimi8TH INTERNATIONAL CONFERENCE ON AMBIENT SYSTEMS, NETWORKS AND TECHNOLOGIES (ANT-2017) AND THE 7TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY INFORMATION TECHNOLOGY (SEIT 2017)

Lehden akronyymiPROCEDIA COMPUT SCI

Vuosikerta109

Aloitussivu327

Lopetussivu334

Sivujen määrä8

ISSN1877-0509

DOIhttps://doi.org/10.1016/j.procs.2017.05.359

Rinnakkaistallenteen osoitehttps://research.utu.fi/converis/portal/detail/Publication/28460710


Tiivistelmä
Health monitoring systems based on Internet-of-things (IoT) have been recently introduced to improve the quality of health care services. However, the number of advanced IoT-based continuous glucose monitoring systems is small and the existing systems have several limitations. In this paper we study feasibility of invasive and continuous glucose monitoring (CGM) system utilizing IoT based approach. We designed an IoT-based system architecture from a sensor device to a back-end system for presenting real-time glucose, body temperature and contextual data (i.e. environmental temperature) in graphical and human-readable forms to end-users such as patients and doctors. In addition, nRF communication protocol is customized for suiting to the glucose monitoring system and achieving a high level of energy efficiency. Furthermore, we investigate energy consumption of the sensor device and design energy harvesting units for the device. Finally, the work provides many advanced services at a gateway level such as a push notification service for notifying patient and doctors in case of abnormal situations (i.e. too low or too high glucose level). The results show that our system is able to achieve continuous glucose monitoring remotely in real-time. In addition, the results reveal that a high level of energy efficiency can be achieved by applying the customized nRF component, the power management unit and the energy harvesting unit altogether in the sensor device. 1877-0509 (C) 2017 The Authors. Published by Elsevier B.V.

Ladattava julkaisu

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.





Last updated on 2024-26-11 at 10:48