A1 Refereed original research article in a scientific journal

Homogeneous immunoassay for cyclopiazonic acid based upon mimotopes and upconversion-resonance energy transfer




AuthorsPradanas-González Fernando, Peltomaa Riikka, Lahtinen Satu, Luque-Uría Álvaro, Más Vicente, Barderas Rodrigo, Maragos Chris M., Canales Ángeles, Soukka Tero, Benito-Peña Elena, Moreno-Bondi María C.

PublisherElsevier Ltd

Publication year2023

JournalBiosensors and Bioelectronics

Journal name in sourceBiosensors and Bioelectronics

Article number115339

Volume233

DOIhttps://doi.org/10.1016/j.bios.2023.115339

Web address https://doi.org/10.1016/j.bios.2023.115339

Self-archived copy’s web addresshttps://research.utu.fi/converis/portal/detail/Publication/179563967


Abstract

Strains of Penicillium spp. are used for fungi-ripened cheeses and Aspergillus spp. routinely contaminate maize and other crops. Some of these strains can produce toxic secondary metabolites (mycotoxins), including the neurotoxin α-cyclopiazonic acid (CPA). In this work, we developed a homogeneous upconversion-resonance energy transfer (UC-RET) immunoassay for the detection of CPA using a novel epitope mimicking peptide, or mimotope, selected by phage display. CPA-specific antibody was used to isolate mimotopes from a cyclic 7-mer peptide library in consecutive selection rounds. Enrichment of antibody binding phages was achieved, and the analysis of individual phage clones revealed four different mimotope peptide sequences. The mimotope sequence, ACNWWDLTLC, performed best in phage-based immunoassays, surface plasmon resonance binding analyses, and UC-RET-based immunoassays. To develop a homogeneous assay, upconversion nanoparticles (UCNP, type NaYF4:Yb3+, Er3+) were used as energy donors and coated with streptavidin to anchor the synthetic biotinylated mimotope. Alexa Fluor 555, used as an energy acceptor, was conjugated to the anti-CPA antibody fragment. The homogeneous single-step immunoassay could detect CPA in just 5 min and enabled a limit of detection (LOD) of 30 pg mL−1 (1.5 μg kg−1) and an IC50 value of 0.36 ng mL−1. No significant cross-reactivity was observed with other co-produced mycotoxins. Finally, we applied the novel method for the detection of CPA in spiked maize samples using high-performance liquid chromatography coupled to a diode array detector (HPLC-DAD) as a reference method.


Downloadable publication

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.





Last updated on 2025-27-03 at 21:49