A1 Refereed original research article in a scientific journal
A retrospective evaluation of Bayesian-penalized likelihood reconstruction for [15O]H2O myocardial perfusion imaging
Authors: Siekkinen Reetta, Han Chunlei, Maaniitty Teemu, Teräs Mika, Knuuti Juhani, Saraste Antti, Teuho Jarmo
Publication year: 2023
Journal: Journal of Nuclear Cardiology
Journal name in source: Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology
Journal acronym: J Nucl Cardiol
Volume: 30
First page : 1602
Last page: 1612
ISSN: 1071-3581
eISSN: 1532-6551
DOI: https://doi.org/10.1007/s12350-022-03164-5
Self-archived copy’s web address: https://research.utu.fi/converis/portal/detail/Publication/178530507
Additional information: Correction to: A retrospective evaluation of Bayesian-penalized likelihood reconstruction for [15O]H2O myocardial perfusion imaging. https://doi.org/10.1007/s12350-023-03253-z
Background: New Block-Sequential-Regularized-Expectation-Maximization (BSREM) image reconstruction technique has been introduced for clinical use mainly for oncologic use. Accurate and quantitative image reconstruction is essential in myocardial perfusion imaging with positron emission tomography (PET) as it utilizes absolute quantitation of myocardial blood flow (MBF). The aim of the study was to evaluate BSREM reconstruction for quantitation in patients with suspected coronary artery disease (CAD).
Methods and results: We analyzed cardiac [15O]H2O PET studies of 177 patients evaluated for CAD. Differences between BSREM and Ordered-Subset-Expectation-Maximization with Time-Of-Flight (TOF) and Point-Spread-Function (PSF) modeling (OSEM-TOF-PSF) in terms of MBF, perfusable tissue fraction, and vascular volume fraction were measured. Classification of ischemia was assessed between the algorithms. OSEM-TOF-PSF and BSREM provided similar global stress MBF in patients with ischemia (1.84 ± 0.21 g⋅ml-1⋅min-1 vs 1.86 ± 0.21 g⋅ml-1⋅min-1) and no ischemia (3.26 ± 0.34 g⋅ml-1⋅min-1 vs 3.28 ± 0.34 g⋅ml-1⋅min-1). Global resting MBF was also similar (0.97 ± 0.12 g⋅ml-1⋅min-1 and 1.12 ± 0.06 g⋅ml-1⋅min-1). The largest mean relative difference in MBF values was 7%. Presence of myocardial ischemia was classified concordantly in 99% of patients using OSEM-TOF-PSF and BSREM reconstructions CONCLUSION: OSEM-TOF-PSF and BSREM image reconstructions produce similar MBF values and diagnosis of myocardial ischemia in patients undergoing [15O]H2O PET due to suspected obstructive coronary artery disease.
Downloadable publication This is an electronic reprint of the original article. |