A1 Vertaisarvioitu alkuperäisartikkeli tieteellisessä lehdessä

Modulating the Geometry of the Carbon Nanofiber Electrodes Provides Control over Dopamine Sensor Performance




TekijätKousar Ayesha, Pande Ishan, Pascual Laura F., Peltola Emilia, Sainio Jani, Laurila Tomi

KustantajaAmerican Chemical Society

Julkaisuvuosi2023

JournalAnalytical Chemistry

Tietokannassa oleva lehden nimiAnalytical Chemistry

Vuosikerta95

Numero5

Aloitussivu2589

Lopetussivu3120

DOIhttps://doi.org/10.1021/acs.analchem.2c04843

Verkko-osoitehttps://doi.org/10.1021/acs.analchem.2c04843

Rinnakkaistallenteen osoitehttps://research.utu.fi/converis/portal/detail/Publication/178526600


Tiivistelmä

One of the major challenges for in vivo electrochemical measurements of dopamine (DA) is to achieve selectivity in the presence of interferents, such as ascorbic acid (AA) and uric acid (UA). Complicated multimaterial structures and ill-defined pretreatments have been frequently utilized to enhance selectivity. The lack of control over the realized structures has prevented establishing associations between the achieved selectivity and the electrode structure. Owing to their easily tailorable structure, carbon nanofiber (CNF) electrodes have become promising materials for neurobiological applications. Here, a novel yet simple strategy to control the sensitivity and selectivity of CNF electrodes toward DA is reported. It consists of adjusting the lengths of CNF by modulating the growth phase during the fabrication process while keeping the surface chemistries similar. It was observed that the sensitivity of the CNF electrodes toward DA was enhanced with the increase in the fiber lengths. More importantly, the increase in the fiber length induced (i) an anodic shift in the DA oxidation peak and (ii) a cathodic shift in the AA oxidation peak. As the UA oxidation peak remained unaffected at high anodic potentials, the electrodes with long CNFs showed excellent selectivity. Electrodes without proper fibers showed only a single broad peak in the solution of AA, DA, and UA, completely lacking the ability to discriminate DA. Hence, the simple strategy of controlling CNF length without the need to carry out any complex chemical treatments provides us a feasible and robust route to fabricate electrode materials for neurotransmitter detection with excellent sensitivity and selectivity.


Ladattava julkaisu

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.





Last updated on 2025-27-03 at 21:42