A1 Vertaisarvioitu alkuperäisartikkeli tieteellisessä lehdessä

Mechanical Properties Evaluation of Three Different Materials for Implant Supported Overdenture: An In-Vitro Study




TekijätGibreel Mona, Perea-Lowery Leila, Lassila Lippo, Vallittu Pekka K

KustantajaMDPI

Julkaisuvuosi2022

Lehti:Materials

Tietokannassa oleva lehden nimiMATERIALS

Lehden akronyymiMATERIALS

Artikkelin numero 6858

Vuosikerta15

Numero19

Sivujen määrä9

eISSN1996-1944

DOIhttps://doi.org/10.3390/ma15196858

Verkko-osoitehttps://www.mdpi.com/1996-1944/15/19/6858

Rinnakkaistallenteen osoitehttps://research.utu.fi/converis/portal/detail/Publication/176862687


Tiivistelmä

Aim:

the aim of this study was to compare the flexural strength and elastic modulus of three-dimensionally (3D) printed, conventional heat-cured, and high-impact implant-supported overdenture materials specimens.

Materials and Methods:

Thirty implant-supported overdenture materials specimens (bar-shaped, 65.0 x 10.2 x 5.1 +/- 0.2 mm(3)) with one central hole were fabricated using 3D-printed, heat-cured conventional, and high-impact denture base resins (n = 10/group). Autopolymerizing acrylic resin was used to attach titanium matrix housings to the central holes of the specimens. A three-point bending test was conducted using a universal testing machine and a model analog with a crosshead speed of 5 mm/min. The indicative flexural strength and elastic modulus were recorded. Data were statistically analyzed using analysis of variance (ANOVA) and the Tukey tests at alpha = 0.05.

Results:

One-way ANOVA revealed a significant effect of denture base material on the flexural strength (p < 0.001) but not on the elastic modulus (p = 0.451) of the evaluated materials. The flexural strength of the 3D-printed specimens (95.99 +/- 9.87 MPa) was significantly higher than the conventional (77.18 +/- 9.69 MPa; p < 0.001) and high-impact ones (82.74 +/- 7.73 MPa; p = 0.002).

Conclusions:

The maximum flexural strength was observed in the 3D-printed implant-supported overdenture material specimens, which might indicate their suitability as an alternative to the conventionally fabricated ones. Flexural strength and elastic modulus of conventional and high-impact heat-cured implant-supported overdenture materials specimens were comparable.


Ladattava julkaisu

This is an electronic reprint of the original article.
This reprint may differ from the original in pagination and typographic detail. Please cite the original version.





Last updated on 2024-26-11 at 15:30