Vertaisarvioitu alkuperäisartikkeli tai data-artikkeli tieteellisessä aikakauslehdessä (A1)
Single-step noncompetitive immunocomplex immunoassay for rapid aflatoxin detection
Julkaisun tekijät: Peltomaa Riikka, Abbas Asmaa, Yli-Mattila Tapani, Lamminmäki Urpo
Kustantaja: Elsevier Ltd
Julkaisuvuosi: 2022
Journal: Food Chemistry
Tietokannassa oleva lehden nimi: Food Chemistry
Artikkelin numero: 133287
Volyymi: 392
eISSN: 1873-7072
DOI: http://dx.doi.org/10.1016/j.foodchem.2022.133287
Verkko-osoite: https://doi.org/10.1016/j.foodchem.2022.133287
Rinnakkaistallenteen osoite: https://research.utu.fi/converis/portal/detail/Publication/175544789
Owing to the high carcinogenicity of aflatoxins, these toxic secondary metabolites pose a severe risk to human and animal health and can have major economic implications. Herein, we report the development of a noncompetitive immunoassay for aflatoxins based on a monoclonal capture antibody and a unique anti-immunocomplex (anti-IC) antibody fragment (scFv) isolated from a synthetic antibody repertoire. The anti-IC scFv recognizes the immunocomplex and enables the development of noncompetitive sandwich-type assays despite the small size of the analyte. The single-step assay developed in this work, with a detection limit of 70 pg mL−1, could detect aflatoxins within 15 min. The assay was applied to the analysis of spiked food samples, and the results showed that the method could provide a rapid and simple tool for aflatoxin detection. Moreover, the work demonstrates the potential of anti-IC antibodies and non-competitive immunoassays for the analysis of small molecule contaminants.