A1 Vertaisarvioitu alkuperäisartikkeli tieteellisessä lehdessä

Cerebral oxygen desaturation events during and functional outcomes after prehospital anaesthesia: A prospective pilot study




TekijätNurmi Jouni, Laukkanen-Nevala Päivi, Kirves Hetti, Raatiniemi Lasse, Toivonen Tuukka, Tommila Miretta, Piiroinen Heini, Setälä Piritta, Karhivuori Pamela, Tukia Simo, Olkinuora Anna

KustantajaWILEY

Julkaisuvuosi2022

JournalActa Anaesthesiologica Scandinavica

Tietokannassa oleva lehden nimiACTA ANAESTHESIOLOGICA SCANDINAVICA

Lehden akronyymiACTA ANAESTH SCAND

Vuosikerta66

Numero6

Aloitussivu750

Lopetussivu758

Sivujen määrä9

ISSN0001-5172

eISSN1399-6576

DOIhttps://doi.org/10.1111/aas.14066

Verkko-osoitehttps://onlinelibrary.wiley.com/doi/10.1111/aas.14066

Rinnakkaistallenteen osoitehttps://research.utu.fi/converis/portal/detail/Publication/175201980


Tiivistelmä

Background: During prehospital anaesthesia, oxygen delivery to the brain might be inadequate to match the oxygen consumption, with unknown long-term functional outcomes. We aimed to evaluate the feasibility of monitoring cerebral oxygenation during prehospital anaesthesia and determining the long-term outcomes.

Methods: We performed a prospective observational feasibility study in two helicopter emergency medical services units. Frontal lobe regional oxygen saturation (rSO(2)) of adult patients undergoing prehospital anaesthesia was monitored with near-infrared spectroscopy (NIRS) by a Nonin H500 oximeter. The outcome was evaluated with a modified Rankin Scale (mRS) at 30 days and 1 year. Health-related quality of life (HRQoL) was measured with a 15D instrument at 1 year.

Results: Of 101 patients enrolled, 83 were included. The mean baseline rSO(2) was 79% (73-84). Desaturation for at least 5 min to rSO(2) below 50% or a decrease of 10% from baseline occurred in four (5%, 95% CI 2%-12%) and 19 (23%, 95% CI 15-93) patients. At 1 year, 32 patients (53%, 95% CI 41-65) achieved favourable neurological outcomes. The median 15D score was 0.889 (Q1-Q3, 0.796-0.970).

Conclusion: Monitoring cerebral oxygenation with a hand-held oximeter during prehospital anaesthesia and collecting data on functional outcomes and HRQoL are feasible. Only half of the patients achieved a favourable functional outcome. The effects of cerebral oxygenation on outcomes during prehospital critical care need to be assessed in future studies.