A1 Vertaisarvioitu alkuperäisartikkeli tieteellisessä lehdessä
Automated GMP production and long-term experience in radiosynthesis of the SV2A tracer [11C]UCB-J; 
Tekijät: Wahlroos, Saara; Krzyczmonik, Anna; Helin, Semi; Rajander, Johan; Solin, Olof; Kirjavainen, Anna K.
Kustantaja: Springer Science and Business Media LLC
Julkaisuvuosi: 2026
Lehti: EJNMMI Radiopharmacy and Chemistry
Artikkelin numero: 44
Vuosikerta: 11
Numero: 1
eISSN: 2365-421X
DOI: https://doi.org/10.1186/s41181-025-00377-0
Julkaisun avoimuus kirjaamishetkellä: Avoimesti saatavilla
Julkaisukanavan avoimuus : Kokonaan avoin julkaisukanava
Verkko-osoite: https://doi.org/10.1186/s41181-025-00377-0
Rinnakkaistallenteen osoite: https://research.utu.fi/converis/portal/detail/Publication/527080563
Rinnakkaistallenteen lisenssi: CC BY
Rinnakkaistallennetun julkaisun versio: Kustantajan versio
Background
Positron emission tomography (PET) is a non-invasive imaging technique that enables the quantification of specific biological and pharmacological processes in vivo. PET can be used to investigate synaptic density by targeting synaptic vesicle glycoprotein 2A (SV2A), and can measure brain levels of SV2A in patients with epilepsy and other neurologic, neurodegenerative, or psychiatric conditions that involve SV2A. The well-known radiotracer [11C]UCB-J ((R)-1-((3-[11C]methylpyridin-4-yl)methyl)-4-(3,4,5-trifluorophenyl)pyrrolidin-2-one) targets SV2A and thereby enables visualization of synaptic density in vivo.
Results
[11C]UCB-J synthesis was performed using [11C]methyl iodide ([11C]CH3I) produced with a commercial device. Here, we present an in-house-built device for [11C]UCB-J production from [11C]CH3I and a suitably treated boronated precursor. The whole radiosynthetic procedure was automated, and has now been in clinical production according to GMP for more than four years. We also address several issues encountered during the production process development and tracer utilisation.
Conclusions
The developed method enables robust [11C]UCB-J production, with a yield of 2.8 ± 0.6 GBq and molar activity of 150 ± 51 GBq/µmol (n = 56) at end of synthesis. The product fulfils all specifications set for a clinical tracer. GMP regulations and guidelines in all aspects of radiopharmaceutical preparation were followed. Although [11C]UCB-J production is challenging, good and reliable radiochemical yields can be obtained by using a carefully designed production protocol.
Ladattava julkaisu This is an electronic reprint of the original article. |
Julkaisussa olevat rahoitustiedot:
This study was financially supported by grants from the Academy of Finland (No. 334310), the Svenska Kulturfonden (No. 151484), and Turun Yliopistollinen Keskussairaala (Nos. 13250 and 11133).