Early and latepace-makerimplantation after transcatheter and surgical aortic valve replacement
Tekijät: Fausto Biancari, Jouni Pykäri, Mikko Savontaus, Mika Laine, Annastiina Husso, Marko Virtanen, Pasi Maaranen, Matti Niemelä, Timo Mäkikallio, Tuomas Tauriainen, Markku Eskola, Peter Raivio, Antti Valtola, Tatu Juvonen, Juhani Airaksinen
Kustantaja: WILEY
Julkaisuvuosi: 2020
Journal: Catheterization and Cardiovascular Interventions
Tietokannassa oleva lehden nimi: CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS
Lehden akronyymi: CATHETER CARDIO INTE
Sivujen määrä: 9
ISSN: 1522-1946
DOI: https://doi.org/10.1002/ccd.29177
Tiivistelmä
Background Conduction defects requiring permanent pacemaker (PPM) implantation are frequent complications occurring after surgical (SAVR) and transcatheter aortic valve replacement (TAVR). Methods Patients who underwent TAVR or SAVR with a bioprosthesis from the nationwide FinnValve registry were the subjects of this study. Patients with prior PPM, who received a sutureless prosthesis, or required cardiac resynchronization therapy or implantable cardioverter defibrillator were excluded from this analysis. Results Four thousand and ten patients underwent SAVR and 1,897 underwent TAVR. TAVR had an increased risk of PPM implantation at 30-day (10.1% vs. 3.5%, unadjusted OR 3.11, 95%CI 2.56-3.87) and 5-year (15.7% vs. 8.6%, unadjusted SHR, 2.12, 95%CI 1.81-2.48) compared to SAVR. PPM implantation within 30 days from the index procedure did not increase the risk of 5-year mortality after either SAVR or TAVR. Among 1,042 propensity score matched pairs, TAVR had an increased risk of PPM implantation at 30-day (9.9% vs. 4.7%,p< .0001) and 5-year (14.7% vs. 11.4%,p= .001), but late (>30 days) PPM implantation at 5-year (4.7% vs. 6.9% SHR 0.72, 95%CI 0.47-1.10) was comparable to SAVR. The types of prosthesis had an impact on 30-day PPM implantation after TAVR, but not on late (>30 days) PPM implantation. Conclusions Although the risk of 30-day PPM implantation is higher after TAVR compared to SAVR, late (>30 days) PPM implantation was comparable with these treatment methods. PPM implantation within 30 days did not affect late survival.
Background Conduction defects requiring permanent pacemaker (PPM) implantation are frequent complications occurring after surgical (SAVR) and transcatheter aortic valve replacement (TAVR). Methods Patients who underwent TAVR or SAVR with a bioprosthesis from the nationwide FinnValve registry were the subjects of this study. Patients with prior PPM, who received a sutureless prosthesis, or required cardiac resynchronization therapy or implantable cardioverter defibrillator were excluded from this analysis. Results Four thousand and ten patients underwent SAVR and 1,897 underwent TAVR. TAVR had an increased risk of PPM implantation at 30-day (10.1% vs. 3.5%, unadjusted OR 3.11, 95%CI 2.56-3.87) and 5-year (15.7% vs. 8.6%, unadjusted SHR, 2.12, 95%CI 1.81-2.48) compared to SAVR. PPM implantation within 30 days from the index procedure did not increase the risk of 5-year mortality after either SAVR or TAVR. Among 1,042 propensity score matched pairs, TAVR had an increased risk of PPM implantation at 30-day (9.9% vs. 4.7%,p< .0001) and 5-year (14.7% vs. 11.4%,p= .001), but late (>30 days) PPM implantation at 5-year (4.7% vs. 6.9% SHR 0.72, 95%CI 0.47-1.10) was comparable to SAVR. The types of prosthesis had an impact on 30-day PPM implantation after TAVR, but not on late (>30 days) PPM implantation. Conclusions Although the risk of 30-day PPM implantation is higher after TAVR compared to SAVR, late (>30 days) PPM implantation was comparable with these treatment methods. PPM implantation within 30 days did not affect late survival.