Bond strength of composite resin luting cements to fiber-reinforced composite root canal posts




Le Bell-Rönnlöf AM, Lahdenperä M, Lassila LV, Vallittu PK

PublisherJaypee Brothers Medical Publishers (P) Ltd

2007

Journal of Contemporary Dental Practice

The journal of contemporary dental practice

J Contemp Dent Pract

8

6

17

24

1526-3711

1526-3711

DOIhttps://doi.org/https://www.thejcdp.com/doi/JCDP/pdf/10.5005/jcdp-8-6-17



The aim of this study was to compare the attachment of different composite resin luting cements to a fiber-reinforced composite (FRC) post with a semi-interpenetrating polymer network polymer matrix.\nSix different brands of composite resin luting cement stubs were applied on the surface of FRC post material and light-cured for 40 seconds. Shear bond strengths of luting cement stubs were measured using a universal testing machine.\nThe differences in shear bond strengths between the cements were not statistically significant.\nAll of the tested composite resin luting cements provided acceptable attachment to the tested FRC post. The tested FRC post material is suitable to use with different composite resin luting cements.\nAIMS\nMETHODS AND MATERIALS\nRESULTS\nCONCLUSION


Last updated on 2024-26-11 at 20:09