Predictors of poor outcomes following deep infection after internal fixation of ankle fractures




Ovaska MT, Makinen TJ, Madanat R, Vahlberg T, Hirvensalo E, Lindahl J

PublisherELSEVIER SCI LTD

2013

Injury

INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED

INJURY

7

44

7

1002

1006

5

0020-1383

DOIhttps://doi.org/10.1016/j.injury.2013.02.027



Our study showed that smoking, postoperative malreduction and hardware removal prior to fracture union were the most important factors predisposing to a permanent complication following an ankle fracture infection. We recommend that hardware be removed only after fracture union has been confirmed. (C) 2013 Elsevier Ltd. All rights reserved.