Assessment of metal ion concentration in water with structured feature selection




Naula P, Airola A, Pihlasalo S, Perez IM, Salakoski T, Pahikkala T

PublisherPERGAMON-ELSEVIER SCIENCE LTD

2017

Chemosphere

CHEMOSPHERE

CHEMOSPHERE

185

1063

1071

9

0045-6535

DOIhttps://doi.org/10.1016/j.chemosphere.2017.07.079



We propose a cost-effective system for the determination of metal ion concentration in water, addressing a central issue in water resources management. The system combines novel luminometric label array technology with a machine learning algorithm that selects a minimal number of array reagents (modulators) and liquid sample dilutions, such that enable accurate quantification. The algorithm is able to identify the optimal modulators and sample dilutions leading to cost reductions since less manual labour and resources are needed. Inferring the ion detector involves a unique type of a structured feature selection problem, which we formalize in this paper. We propose a novel Cartesian greedy forward feature selection algorithm for solving the problem. The novel algorithm was evaluated in the concentration assessment of five metal ions and the performance was compared to two known feature selection approaches. The results demonstrate that the proposed system can assist in lowering the costs with minimal loss in accuracy. (c) 2017 Elsevier Ltd. All rights reserved.



Last updated on 2024-26-11 at 21:28