Effect of Water Temperature on Cyclic Fatigue Properties of Glass-fiber-reinforced Hybrid Composite Resin and Its Fracture Pattern After Flexural Testing




Kuroda S, Shinya A, Vallittu PK, Nakasone Y, Shinya A

PublisherQUINTESSENCE PUBLISHING CO INC

2013

Journal of Adhesive Dentistry

JOURNAL OF ADHESIVE DENTISTRY

J ADHES DENT

1

15

1

19

26

8

1461-5185

DOIhttps://doi.org/10.3290/j.jad.a28884



Conclusion: Reduced numbers of cycles to fracture and lower fatigue values were observed as both the maximum load and immersion temperature increased.