A1 Refereed original research article in a scientific journal
Magnetic resonance-only simulation and dose calculation in external beam radiation therapy: a feasibility study for pelvic cancers
Authors: Kemppainen R, Suilamo S, Tuokkola T, Lindholm P, Deppe MH, Keyrilainen J
Publisher: TAYLOR & FRANCIS LTD
Publication year: 2017
Journal: Acta Oncologica
Journal name in source: ACTA ONCOLOGICA
Journal acronym: ACTA ONCOL
Volume: 56
Issue: SI 6
First page : 792
Last page: 798
Number of pages: 7
ISSN: 0284-186X
eISSN: 1651-226X
DOI: https://doi.org/10.1080/0284186X.2017.1293290
Abstract
Background: The clinical feasibility of using pseudo-computed tomography (pCT) images derived from magnetic resonance (MR) images for external bean radiation therapy (EBRT) planning for prostate cancer patients has been well demonstrated. This paper investigates the feasibility of applying an MR-derived, pCT planning approach to additional types of cancer in the pelvis.Material and methods: Fifteen patients (five prostate cancer patients, five rectal cancer patients, and five gynecological cancer patients) receiving EBRT at Turku University Hospital (Turku, Finland) were included in the study. Images from an MRCAT (Magnetic Resonance for Calculating ATtenuation, Philips, Vantaa, Finland) pCT method were generated as a part of a clinical MR-simulation procedure. Dose calculation accuracy was assessed by comparing the pCT-based calculation with a CT-based calculation. In addition, the degree of geometric accuracy was studied.Results: The median relative difference of PTV mean dose between CT and pCT images was within 0.8% for all tumor types. When assessing the tumor site-specific accuracy, the median [range] relative dose differences to the PTV mean were 0.7 [-0.11;1.05]% for the prostate cases, 0.3 [-0.25;0.57]% for the rectal cases, and 0.09 [-0.69;0.25]% for the gynecological cancer cases. System-induced geometric distortion was measured to be less than 1mm for all PTV volumes and the effect on the PTV median dose was less than 0.1%.Conclusions: According to the comparison, using pCT for clinical EBRT planning and dose calculation in the three investigated types of pelvic cancers is feasible. Further studies are required to demonstrate the applicability to a larger cohort of patients.
Background: The clinical feasibility of using pseudo-computed tomography (pCT) images derived from magnetic resonance (MR) images for external bean radiation therapy (EBRT) planning for prostate cancer patients has been well demonstrated. This paper investigates the feasibility of applying an MR-derived, pCT planning approach to additional types of cancer in the pelvis.Material and methods: Fifteen patients (five prostate cancer patients, five rectal cancer patients, and five gynecological cancer patients) receiving EBRT at Turku University Hospital (Turku, Finland) were included in the study. Images from an MRCAT (Magnetic Resonance for Calculating ATtenuation, Philips, Vantaa, Finland) pCT method were generated as a part of a clinical MR-simulation procedure. Dose calculation accuracy was assessed by comparing the pCT-based calculation with a CT-based calculation. In addition, the degree of geometric accuracy was studied.Results: The median relative difference of PTV mean dose between CT and pCT images was within 0.8% for all tumor types. When assessing the tumor site-specific accuracy, the median [range] relative dose differences to the PTV mean were 0.7 [-0.11;1.05]% for the prostate cases, 0.3 [-0.25;0.57]% for the rectal cases, and 0.09 [-0.69;0.25]% for the gynecological cancer cases. System-induced geometric distortion was measured to be less than 1mm for all PTV volumes and the effect on the PTV median dose was less than 0.1%.Conclusions: According to the comparison, using pCT for clinical EBRT planning and dose calculation in the three investigated types of pelvic cancers is feasible. Further studies are required to demonstrate the applicability to a larger cohort of patients.