A1 Refereed original research article in a scientific journal

Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty




AuthorsMokka J, Junnila M, Seppanen M, Virolainen P, Polonen T, Vahlberg T, Mattila K, Tuominen EKJ, Rantakokko J, Äärimaa V, Kukkonen J, Makela KT

PublisherINFORMA HEALTHCARE

Publication year2013

JournalActa Orthopaedica

Journal name in sourceACTA ORTHOPAEDICA

Journal acronymACTA ORTHOP

Number in series6

Volume84

Issue6

First page 549

Last page554

Number of pages6

ISSN1745-3674

DOIhttps://doi.org/10.3109/17453674.2013.859419


Abstract
Interpretation ARMD is common after ReCap-M2a-Magnum total hip arthroplasty, and we discourage the use of this device. Asymptomatic patients with a small fluid collection on MRI may not need instant revision surgery but must be followed up closely.