Abstract
The heterogeneous immunoassay of thyroid stimulating hormone (TSH) was detected by the time-resolved cathodic electrochemiluminescence immunoassay (tr-CECLIA) method using magnetic beads as a mobile support. The magnetic beads coated with sandwich type TSH immunoassay were captured with a magnet for washing and detection processes. The time-resolved cathodic electrochemiluminescence (tr-CECL) signal of Tb(III) chelate label was generated by cathodic pulse polarization in the aluminum working electrode and platinum counter electrode system. The detection method causes injection of high energy electrons into the aqueous solution near the aluminum electrode and creates rigid simultaneous oxidative and reductive conditions that excitate the Tb(III) chelate used as a label luminophore in the heterogeneous sandwich type immunoassay of TSH in the surface of the magnetic beads. The limit of detection of the method was about 50 mIU L-1. The precision of it was noticed to be good; the coefficient variation percentage was realized to be lower than 10 %. Unfortunately the limit of detection is not good enough for determination of analyte levels of very low concentrations for instance TSH in body fluids. The possible application areas of the method are in highly sophisticated micro or nano fluidic detection and sensor systems where the aspiration level of the analyte detection limit is not very high and the mobility and manageability and the large surface area of the magnetic beads can be utilized efficiently in separating, washing, moving, coating and detecting processes. In the case of tr-CECLIA the presented method makes possible to use multipurpose working electrodes instead of disposable ones. (C) 2017 Elsevier B.V. All rights reserved.
The heterogeneous immunoassay of thyroid stimulating hormone (TSH) was detected by the time-resolved cathodic electrochemiluminescence immunoassay (tr-CECLIA) method using magnetic beads as a mobile support. The magnetic beads coated with sandwich type TSH immunoassay were captured with a magnet for washing and detection processes. The time-resolved cathodic electrochemiluminescence (tr-CECL) signal of Tb(III) chelate label was generated by cathodic pulse polarization in the aluminum working electrode and platinum counter electrode system. The detection method causes injection of high energy electrons into the aqueous solution near the aluminum electrode and creates rigid simultaneous oxidative and reductive conditions that excitate the Tb(III) chelate used as a label luminophore in the heterogeneous sandwich type immunoassay of TSH in the surface of the magnetic beads. The limit of detection of the method was about 50 mIU L-1. The precision of it was noticed to be good; the coefficient variation percentage was realized to be lower than 10 %. Unfortunately the limit of detection is not good enough for determination of analyte levels of very low concentrations for instance TSH in body fluids. The possible application areas of the method are in highly sophisticated micro or nano fluidic detection and sensor systems where the aspiration level of the analyte detection limit is not very high and the mobility and manageability and the large surface area of the magnetic beads can be utilized efficiently in separating, washing, moving, coating and detecting processes. In the case of tr-CECLIA the presented method makes possible to use multipurpose working electrodes instead of disposable ones. (C) 2017 Elsevier B.V. All rights reserved.