A1 Refereed original research article in a scientific journal
Titanium-Nitride-Oxide-Coated vs Everolimus-Eluting Stents in Acute Coronary Syndrome 5-Year Clinical Outcomes of the TIDES-ACS Randomized Clinical Trial
Authors: Bouisset Frederic, Sia Jussi, Mizukami Takuya, Karjalainen Pasi P, Tonino Pim AL, Pijls Nico HJ, van der Heyden Jan, Romppanen Hannu, Kervinen Kari, Airaksinen Juhani KE, Lalmand Jaques, Frambach Peter, da Costa Bruno R, Collet Carlos, De Bruyne Bernard; TIDES-ACS Study Grp
Publisher: AMER MEDICAL ASSOC
Publication year: 2023
Journal: JAMA Cardiology
Journal name in source: JAMA CARDIOLOGY
Journal acronym: JAMA CARDIOL
Volume: 8
Issue: 7
First page : 703
Last page: 708
Number of pages: 5
ISSN: 2380-6583
eISSN: 2380-6591
DOI: https://doi.org/10.1001/jamacardio.2023.1373
Importance: Titanium-nitride-oxide (TiNO)-coated stents show faster strut coverage compared with drug-eluting stents without excessive intimal-hyperplasia observed in bare metal stents. It is important to study long-term clinical outcomes after treatment of patients with an acute coronary syndrome (ACS) by TiNO-coated stents, which are neither drug-eluting stents nor bare metal stents.
Objective: To compare the rate of main composite outcome of cardiac death, myocardial infarction (MI), or ischemia-driven target lesion revascularization at 5 years in patients with ACS randomized to receive either a TiNO-coated stent or a third-generation everolimus-eluting stent (EES).
Design, setting, and participants: This multicenter, randomized, controlled, open-label trial was conducted in 12 clinical sites in 5 European countries and enrolled patients from January 2014 to August 2016. Patients presenting with ACS (ST-segment elevation MI, non-ST-segment elevation MI, and unstable angina) with at least 1 de novo lesion were randomized to receive either a TiNO-coated stent or an EES. The present report analyzes the long-term follow-up for the main composite outcome and its individual components. Analysis took place between November 2022 to March 2023.
Main outcome: The primary end point was a composite of cardiac death, MI, or target lesion revascularization at 12-month follow-up.
Results: A total of 1491 patients with ACS were randomly assigned to receive either TiNO-coated stents (989 [66.3%]) or EES (502 [33.7%]). The mean (SD) age was 62.7 (10.8) years, and 363 (24.3%) were female. At 5 years, the main composite outcome events occurred in 111 patients (11.2%) in the TiNO group vs 60 patients (12%) in the EES group (hazard ratio [HR], 0.94; 95% CI, 0.69-1.28; P = .69). The rate of cardiac death was 0.9% (9 of 989) vs 3.0% (15 of 502) (HR, 0.30; 95% CI, 0.13-0.69; P = .005), the rate of MI was 4.6% (45 of 989) vs 7.0% (35 of 502) (HR, 0.64; 95% CI, 0.41-0.99; P = .049), the rate of stent thrombosis was 1.2% (12 of 989) vs 2.8% (14 of 502) (HR, 0.43; 95% CI, 0.20-0.93; P = .034), and the rate of target lesion revascularization was 7.4% (73 of 989) vs 6.4% (32 of 502) (HR, 1.16; 95% CI, 0.77-1.76; P = .47) in the TiNO-coated stent arm and in the EES arm, respectively.
Conclusion and relevance: In this study, patients with ACS had a main composite outcome that was not different 5 years after TiNO-coated stent or EES.