Comparison of two different sampling intervals for optical coherence tomography evaluation of neointimal healing response after coronary stent implantation




TekijätVarho V, Nammas W, Kiviniemi TO, Sia J, Romppanen H, Pietilä M, Airaksinen JK, Karjalainen PP

Julkaisuvuosi2017

JournalInternational Journal of Cardiology

Vuosikerta227

Aloitussivu194

Lopetussivu200

Sivujen määrä7

ISSN0167-5273

DOIhttps://doi.org/10.1016/j.ijcard.2016.11.173


Tiivistelmä
BACKGROUND/OBJECTIVES:

Optical coherence tomography (OCT) is widely used for evaluation of healing response to stent implantation. We sought to test the agreement between the 1-mm and 0.6-mm sampling intervals for assessment of the percentage of uncovered and malapposed struts by OCT.

METHODS:

Thirty-eight patients presenting with acute coronary syndrome were randomized to receive either a titanium-nitride-oxide-coated stent (n=19) or an everolimus-eluting stent (n=19). Neointimal strut coverage and strut apposition were evaluated by OCT at 2-month follow-up. Two independent investigators performed offline OCT image analysis at 1-mm intervals. One investigator repeated the measurements at 0.6-mm intervals and measurements were compared between the two sampling intervals.

RESULTS:

At a median follow-up of 60 [8] days, 694 cross-sections (7603 struts) and 1138 cross-sections (12,331 struts) were analysed at 1-mm and at 0.6-mm intervals, respectively. The median [IQR] percentage of uncovered struts was 3.27% [11.1] versus 3.38% [9.76] (p=0.001), and the mean (±SD) percentage was 7.69±9.99% versus 6.27±8.14% (p=0.004), for the 1-mm sampling interval versus the 0.6-mm sampling interval analysis, respectively; the median percentage of malapposed struts was 0.42% [2.04] versus 0.12% [1.63], respectively, (p=0.003). The intraclass correlation coefficient between the two observers for the percentage of uncovered struts was 0.95.

CONCLUSIONS:

The OCT-evaluated strut-level measurements of neointimal healing after stent implantation differ significantly between the 1-mm and the 0.6-mm sampling intervals.