Objectives
This study sought to evaluate the prognostic value of an increased mean mitral valve pressure gradient (MVG) in patients with primary mitral regurgitation (MR) after transcatheter edge-to-edge repair (TEER).
BackgroundConflicting data exist regarding impact of increased mean MVG on outcomes after TEER.
MethodsThis study included 419 patients with primary MR (mean age 80.6 ± 10.4 years; 40.6% female) who underwent TEER. Patients were divided into quartiles (Qs) based on discharge echocardiographic mean MVG. Primary outcome was the composite endpoint of all-cause mortality and heart failure hospitalization. Secondary outcomes included all-cause mortality and the secondary composite endpoint of all-cause mortality, heart failure hospitalization, and mitral valve reintervention.
ResultsThe median number of MitraClips used was 2 per patient. MR reduction ≤moderate was achieved in 407 (97.1%) patients. Mean MVG was 1.9 ± 0.3 mm Hg, 3.0 ± 0.1 mm Hg, 4.0 ± 0.1 mm Hg, and 6.0 ± 1.2 mm Hg in Q1, Q2, Q3, and Q4, respectively. There was no significant differences across quartiles in the primary outcome (15.4%, 19.6%, 22.0%, and 21.9% in Q1-Q4, respectively; P = 0.63), all-cause mortality (15.9% vs 18.6% vs 19.4% vs 17.1%, respectively; P = 0.91), and the secondary composite endpoint at 2 years (33.3% vs 29.5% vs 22.0% vs 31.6%, respectively; P = 0.37). After multivariate adjustment for baseline clinical and procedural variables, the mean MVG in Q4 compared with Q1 to Q3 was not independently associated with the primary outcome (HR: 1.22; 95% CI: 0.82-1.83; P = 0.33), all-cause mortality, and the secondary composite endpoint.
ConclusionsIncreased mean MVG was not independently associated with adverse events after TEER in patients with primary MR.