A1 Vertaisarvioitu alkuperäisartikkeli tieteellisessä lehdessä

Degree of conversion of dual-polymerizing cements light polymerized through monolithic zirconia of different thicknesses and types




TekijätTaiseer A. Sulaiman, Aous A. Abdulmajeed, Terrence E. Donovan, André V. Ritter, Lippo V. Lassila, Pekka K. Vallittu, Timo O. Närhi

KustantajaMosby, Inc.

Julkaisuvuosi2015

JournalJournal of Prosthetic Dentistry

Vuosikerta114

Numero1

Aloitussivu103

Lopetussivu108

Sivujen määrä6

ISSN0022-3913

DOIhttps://doi.org/10.1016/j.prosdent.2015.02.007


Tiivistelmä

Statement of problem

Monolithic zirconia restorations are increasingly common. Dual-polymerizing cements have been advocated for cementation. The opacious nature of zirconia restoration can attenuate light, compromising optimal resin polymerization and eventually restoration debonding.



Purpose

The purpose of this in vitro study was to evaluate the influence of material thickness on light irradiance, radiant exposure, and the degree of monomer conversion (DC) of 2 dual-polymerizing resin cements light-polymerized through different brands of monolithic zirconia.



Material and methods

Dual-polymerizing resin cements (RelyX Ultimate; 3M-ESPE, and Variolink II; Ivoclar, Vivadent) were mixed according to the manufacturers’ instructions with a film thickness of 40 μm, placed under a 10×10 mm specimen of monolithic zirconia (Prettau Anterior by Zirkonzahn, Katana by Noritake, BruxZir by Glidewell, and Zenostar by Wieland) and a zirconia core control (ICE zirkon by Zirkonzahn) at various thicknesses (0.50, 1.00, 1.50, and 2.00 mm, n=5 of each thickness). Each specimen was irradiated for 20 seconds (RelyX Ultimate) and 40 seconds (Variolink II) with Elipar S10 (3M-ESPE, 1200 mW/cm2). The amount of irradiance and radiant exposure was quantified for each specimen. Fourier transform infrared spectroscopy was used to measure the DC from the bottom surface of the resin. Statistical analysis was performed with 2-way ANOVA and post hoc Tukey honest significant difference (HSD) tests (α=.05).



Results

Light irradiance and radiant exposure decreased as the thickness of the specimen increased (P<.05) regardless of the brand. The ranking from least to highest was BruxZirP<.001). The DC decreased significantly as the thickness of the zirconia increased (P<.001). Katana and Prettau Anterior showed the highest DC and BruxZir showed the lowest.



Conclusion

The thickness of zirconia affects the DC of resin-based cements. The DC of the resin cements differed significantly between cements and among zirconia brands. More polymerizing time may be needed to deliver sufficient energy through some brands of zirconia.