Erratum to: Neointimal coverage and vasodilator response to titanium-nitride-oxide-coated bioactive stents and everolimus-eluting stents in patients with acute coronary syndrome – insights from the BASE-ACS trial




Alaotsikkoinsights from the BASE-ACS trial

TekijätKarjalainen PP, Kiviniemi TO, Lehtinen T, Nammas W, Ylitalo A, Saraste A, Mikkelsson J, Pietila M, Biancari F, Airaksinen JKE

KustantajaSPRINGER

KustannuspaikkaDORDRECHT; VAN GODEWIJCKSTRAAT 30, 3311 GZ DORDRECHT, NETHERLANDS

Julkaisuvuosi2013

JournalInternational Journal of Cardiovascular Imaging

Tietokannassa oleva lehden nimiInternational Journal of Cardiovascular Imaging

Lehden akronyymiInt.J.Cardiovasc.Imaging

Numero sarjassa8

Vuosikerta29

Numero8

Aloitussivu1915

Lopetussivu1915

Sivujen määrä1

ISSN1569-5794

DOIhttps://doi.org/10.1007/s10554-013-0312-9


Tiivistelmä
Incomplete stent endothelialization is associated with late and very late stent thrombosis. In a post hoc analysis of the BASE-ACS trial, we sought to assess neointimal coverage and coronary flow reserve (CFR) 9 months after implantation of titanium-nitride-oxide-coated bioactive stents (BAS) versus everolimus-eluting stents (EES) in patients with acute coronary syndrome (ACS). In the BASE-ACS trial, 827 patients with ACS were randomized to receive either BAS or EES. In the current study, we examined neointimal growth and strut coverage by optical coherence tomography and CFR by trans-thoracic echocardiography in 28 consecutive non-diabetic patients with the culprit lesion in the left anterior descending coronary artery. The primary endpoints were binary stent strut coverage and CFR at 9-month follow-up. A total of 13 patients were included in the BAS group (2,033 struts); 15 in the EES group (2,898 struts). Binary stent strut coverage was higher and malapposed struts lower with BAS versus EES (99.4 vs 89.2, and 0.2 vs 4.6 %, respectively, p < 0.001 for both). Neointimal hyperplasia thickness was greater with BAS versus EES (274.2 vs 100.1 μm, respectively, p < 0.001). CFR was lower with EES versus BAS (2.2 ± 0.8 vs 3.0 ± 0.5, respectively, p = 0.001). Abnormal CFR (<2.5) were detected in 10 patients in the EES group versus one in the BAS group (p = 0.002). The current study demonstrated that in patients with ACS, BAS resulted in improved neointimal stent strut coverage and better coronary vasodilator function as compared with EES at 9-month follow-up.