Development of an immunoassay for the detection of cystatin C dimers




TekijätHyytia H, Ristiniemi N, Airas L, Pettersson K, Hellman J

KustantajaELSEVIER SCIENCE BV

Julkaisuvuosi2010

JournalJournal of Immunological Methods

Tietokannassa oleva lehden nimiJOURNAL OF IMMUNOLOGICAL METHODS

Lehden akronyymiJ IMMUNOL METHODS

Numero sarjassa1-2

Vuosikerta355

Numero1-2

Aloitussivu14

Lopetussivu20

Sivujen määrä7

ISSN0022-1759

DOIhttps://doi.org/10.1016/j.jim.2010.02.014


Tiivistelmä
Human cystatin C (CysC) is a reversible cysteine protease inhibitor, which is abundantly secreted to body fluids. It is a potential marker of kidney dysfunction, but has been suggested to be of diagnostic importance in a number of neurodegenerative diseases, as well. The amyloid formation by a L68Q variant CysC accounts for the hereditary CysC amyloid angiopathy (HCCAA). Also, the wild type CysC forms inactive dimers at partly denaturing conditions through a domain swapping mechanism. Here, we have developed an immunoassay for the detection of dimeric CysC consisting of either a full length or an N-terminally truncated form. A codon optimized gene encoding a full length CysC was expressed in Escherichia coil, where the product was directed to the periplasmic space. Two different forms of CysC were isolated, a full length product and a form proteolytically truncated by 8 N-terminal amino acid residues. In vitro dimerization experiments were conducted in order to enable the selection of monoclonal antibodies for the construction of an immunoassay being able to primarily recognize the dimers. The analytical detection limit of the assay was 0.043 mu g/l, with assay imprecision below 16%. The assay was linear in the range of 5-100 mu g/l (R(2) = 0.997). The dimer assay was employed for the measurement of serum and cerebrospinal fluid (CSF) sample panel of 20 multiple sclerosis (MS) and 22 non-MS patients. A dimer signal was observed in both serum and CSF samples. The dimer signals from CSF were approximately 2-22 times higher (average 13) than the corresponding signals from serum samples. However, the measured signal levels between the different patient groups showed no statistically significant difference in serum or in CSF (P = 0.07 and P = 0.98 respectively). In conclusion, the immunoassay provides direct means for detecting CysC dimers in serum and CSF in respect to the amount of total CysC. (C) 2010 Elsevier B.V. All rights reserved.



Last updated on 2024-26-11 at 12:24